TEST PROCEDURE COVERING MOTORIZED FILING EQUIPMENT, BAY 2, SECTION 3,(Sanitized)

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP74-00005R000100070028-7
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
2
Document Creation Date: 
December 9, 2016
Document Release Date: 
July 12, 2000
Sequence Number: 
28
Case Number: 
Publication Date: 
August 27, 1971
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP74-00005R000100070028-7.pdf98.53 KB
Body: 
25X1C4a n,,4?p!i~~Pr~ker2f@8#,?0fl?ROR07t}028z7t~o........... cr.......... .................. ..,.. 'iofixed.. ilinS:. au" nment...._... Je:. No... .. ..................... Ya nr,. ,; ac,t ............ I3`iY-?2....5~.ct~ os...3.,.. 'slg.. ....................................... u:dcr simulated operating conditions. ?urnose: To establish a test, procedure for the equipment now installed, Units at start of. each test 'cycle. 20st.on and identification (for test purposes only) of Movable T I [. I ~1~ . Z - T A A t I T Aisle E 2 a. Repeat Step la., 25X1A6a To-sit Cy'cle,: 'A complete test cycle shall consist of the movement of the equip- ment through each of the enumerated.steps.belov,'interrupted by a simulated filing, action.. Step' 1. Move Units A,B,C',D & E to Stationary 2 (time, 12 sec.) a. Employee walks to the end of the. first carriage (17 ft.) and slides a box forward to normal operating position and returns box to original position (est,imated time, 48 sec.) Step 2., Move Units E,D,C,B & A to Stationary 1. Step 3. Move'Units B,C,D & E to.Stationary'2. a. Repeat Step.la. 'Step 4. 'Move Units E,D,C & B to _Unit A. a Repeat Step Ia.. Step 5. -Move Units'C,D & E to Stationary 2. a., Repeat Step' la. Step 5. Move Uni.:s E,D & C to Unit B. a. Repeat Step Ia. Step 7.. Move Units D & E to Stationary 2. a. Repeat Step Ia. Step 8. Move Units E & D, to Unit.C. a. Repeat Step Ia. Approved For Release 2000108/24: CIA-RDP74-00005R000100070028-7 Approved For Release 20 2P/jaP~?00007 7r:o........... o,:........... ...... D A ? S.U iii= .. .... ............ J U v ti G................... .D. . Y......... .OA..... .................................. ... .................................. ..... .......................;.. ... ._................ stop 9., Move UnitE to Stationary 2. a. Repeat Step la. Step 10. Move Unit E to Unit D. a. Repeat Step la.. Upon completion of.above cycle each possible combination of Movable Units has bcen moved from left to right and right to left. m~.rain : On the basis of 60 seconds per cycle step a complete test cycle will require 10 minutes resulting in 6 test cycles per hour or 48 for an 8 hour days Each test cycle represents 10~filing actions; an'8 hour day of testing is . equivalent to 480 simulated actions. Normal operations would exceed time allowed for simulated operation due to associated clerical work required after .box is pulled out on shelf. . Monitoring: A full time parson shall be assigned to observe the test to main- that each step in each cycle is l assure twin a continuous record which wil completed. Record shall contain notation of any equipment malfunction as ;elated to any step in any cycle. Test Period: Upon completion of 50 full 10 Step Cycles test shall be con- idered complete. Copy of test record provided in 5. above shall be distri- buted to all persons.concerned. Approved For Release 2000/08/24: CIA-RDP74-QO.005R000100070028=7