Inspection Report No. 6 - HG-100 with (Sanitized)
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP78-02820A001100050001-3
Release Decision:
RIPPUB
Original Classification:
S
Document Page Count:
3
Document Creation Date:
December 9, 2016
Document Release Date:
May 8, 1998
Sequence Number:
1
Case Number:
Publication Date:
October 28, 1965
Content Type:
REPORT
File:
Attachment | Size |
---|---|
CIA-RDP78-02820A001100050001-3.pdf | 102.85 KB |
Body:
?"T'?""` Ued For Release 280'1
/0
tA~ruu
UNITED STATES GOVERNMENT
Memorandum
25X1A
? The Files:
F? OM
SUBJECT: Inspection Report No. 6 - HG-100 with
EP 65-322
DATE: 28 October 1965
1. Project Description:
The HG-100 is a tactical handcranked generator to be used in the
operation of field portable electronic equipment and the charging of
batteries. The unit is to supply 75 watts of average and 150 watts of
peak power at 12 volts. The design goal is for a 10 lb., package of
230 cubic inches.
2. Contractual Information:
25X1 Al a a. Initial Cost: b. Request for Procurement Action: 27 July 1964
c. Initiation Date: 2 January 1965
d. Completion Date: 2 September 1965 Extension: 26 October 1965
e. Deliverable Items: Twenty service test models, monthly reports,
and final report. One prototype.
3. Date of Meeting: 21 October 1965
25X1A 4. Place of Meeting:
5. Persons Attending:
Agency
25X1A9a
Non-Agency
6. Contractor's Performance:
a. On schedule and expected to remain so: Yes
b. Within obligated funds and expected to remain so: Yes
c. Satisfactory technical progress: Yes
7. Project Status:
GROUP I
Etcladed tram snlomIUC
Mrnpndln5 Id
dseissslliestlnn _
Buy U.S. Savings Bonds Regularly 4n the payroll Savings Plan
Approved For Release 200JIQ$/D
25X1A9a
25X1A5a1
25X1A
25X1A5a1
Approved For Release 2001/08/02 : CIOA001100050001-3
EP 65-322
SUBJECT: Inspection Report No. 6 - HG-100 with
7. Project Status':
25X1A5a1
and the personnel associated with him.
is the result of much effort on the part of project engineer, 5X1A5a1
25X1A5a1
25X1A
is completing the HG-100 project on schedule to the day and
Performance of the HG-100 is tabulated on the following "score sheet."
Specification
Actual
Weight 10.0
11.23 (could be significantly
reduced in production by using
a deep drawn aluminum housing)
Voltage regulation 12.0 - 10.8 from
Flat at 11.8 - 11.4 over
0 - 12.5 amps
temperature range, 0 - 12.5
amps
Current regulation 1.9 - 1.7 amps
1.9 - 1.7 amps from 10.5 to
18.5 volts
Ripple 60 mV rms for modes 1, 2, 3
Within specification at all
currents at room and high
temperature, can go to 120 mV
rms at low temperature (-22?F)
Ripple 50 mV rms for mode 4
Meets Specification
Response time .5 milliseconds
Efficiency
Does not fall out of regulation
60% at +70?F
60% (all units tested from
60% at +125 ?F
50% at -22?F-
62% to 68%)
6o%
60% (after short warm up
efficiencies are typical
for full cranking range)
Eght" Ir dmnGu~nd is
~,c~~uitmc_;;on
Approved For Release 2001/08/02 : CIA-RDP78-0282OA001100050001-3
Approved For Release 2001 /08/02 -02820A001100050001-3
EP 65-322
M11JECT: Inspection Report No. 6 - HG-100 with
Specification Actual
Life 500 hours
Temperature
25X1A5a1
25X1A
Gear system tested to 610 hours
at constant 125 watt load. There
are no other life critical com-
ponents
-22?F to +131?F OK
(operating)
-65?F to +165?F OK
(exposure)
Humidity 10 day OK - No evidence of water
intrusion
Water tight OK
Acoustic Noise 55 db on either scale
57 db A scale (field test)
-54+ db B scale
Shock - Drop OK after 20 drops
Final acceptance will, of course, be based on the results of our
on tests but there is little doubt that the unit will perform adequately.
25X1A9a
Distribution:
R&D Subject File
Engineering Section CB/PD/OL
R&D Lab
OC-OS
ESB
Monthly (2)
EP Chrono
01q?O%b8bJr31965 )
25X1A9a