FINAL KE-6 KEYER TESTS
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP78-03424A001200020005-3
Release Decision:
RIPPUB
Original Classification:
C
Document Page Count:
3
Document Creation Date:
December 22, 2016
Document Release Date:
February 16, 2012
Sequence Number:
5
Case Number:
Publication Date:
February 3, 1959
Content Type:
MEMO
File:
Attachment | Size |
---|---|
![]() | 81.16 KB |
Body:
Declassified in Part - Sanitized Copy Approved forrRelease 2~0yy1~ 2/02/1gp6 po: CIA-RDP78-03424AO01200020005-3
STANDARD FORM NO. 84 `#`fo``- S 9{g f ? P Ii./ v A, yyi
office Memorandum UNITED STATES GOVERNMENT
Chief, R&D Branch
DATE:3 February 1959
FROM : Chief, R&D Laboratory
suBJECr: . Final KE-6 Keyer Tests
009
1.11-1435 /0f . _.
1 ~J57 Z' .~~.. r:,. 1;
The attached report describes the results of the final
electrical and mechanical tests conducted on the KE-6 Keyer)
hnr)'JUU 1C-A--VCZT
Attachment:
A&A Report No. 182-C (Part IV)
ORIGINAL CL BY O3.,79#7
o DECL.e REVW ON 2t'*/C~
EXT BYND 6 IB -S
REASON
C0NA[1 G!-N' T
L
Declassified in Part - Sanitized Copy Approved for Release 2012/02/16: CIA-RDP78-03424AO01200020005-3
Declassified in Part - Sanitized Copy Approved for Release 2012/02/16: CIA-RDP78-03424A001200020005-3
A&A Report No. 182-C (Part IV)
CONF~
Project No. 2004-144
3 February 1959
FINAL KE-6 ELECTRICAL AND MECHANICAL TEST RESULTS
ANALYSIS AND APPRAISAL
One KE-6 was delivered to the R&D Laboratory for final tests.
Previous to this date, the unit had been returned to the manu-
facturer for rework to eliminate several electrical and mechan-
ical deficiencies.
2. ELECTRICAL TEST
The keyer performed during the electrical test as follows:
(a) The voltage applied to the motor input terminals is 5.2
volts, DC.
(b) The keyer operated satisfactorily during the keying test.
All characters were transmitted correctly. The keyer did
not exhibit evidence of incorrect keying when the keyer
buttons were not fully depressed.
The keyer transmits the following International Morse Code letters
when the specified numbered buttons are depressed:
Keyer Button International Morse Code
1 A
2 N
3 U
4 R
5 K
6 D
7 L
8 C
9 X
10 F
11 AA
C
II(D 1c_
NFNT 'L
Declassified in Part - Sanitized Copy Approved for Release 2012/02/16: CIA-RDP78-03424A001200020005-3
Declassified in Part - Sanitized Copy Approved for Release 2012/02/16: CIA-RDP78-03424AO01200020005- bz 2
The manufacturer has improved the mechanical features of the
keyer as follows:
(a) A cable clamp has been installed in the keyer to secure
the keyer cable.
(b) The collector ring contact tip has been silver plated.
(c) The individual segment pin contacts beneath each key
button have been raised above the height of the common
contacts. This mechanical improvement eliminates the
possibility of transmitting incorrect characters when
the key is depressed.
The KE-6 Keyer is considered to be a satisfactory device. No
specific recommendations are given.
Declassified in Part - Sanitized Copy Approved for Release 2012/02/16: CIA-RDP78-03424AO01200020005-3