TEST REPORT MILITARY RECORDER MODEL MR-1 26 AUGUST 1959

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78-03424A002000060019-5
Release Decision: 
RIPPUB
Original Classification: 
C
Document Page Count: 
5
Document Creation Date: 
December 22, 2016
Document Release Date: 
September 19, 2011
Sequence Number: 
19
Case Number: 
Publication Date: 
August 26, 1959
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP78-03424A002000060019-5.pdf551.14 KB
Body: 
Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 CONFIDENTIAL MILITARY RECORDER Model MR-1 26 August 1959 WANUAW" 1. Crosstalk Specification: Minimum of 40 db Test: Due to the noise level of the system, evaluation of the crosstalk figure was not obtainable on playback . Record amp crosstalk = more than -70 db. 2. Frequency Response Specification: ?6 db 250 -to 60 Kc Test: CIi 1 1000 - 0 Low -5 High +1 CH 2 1000 ' = 0 Low -4 High +1.5 CH 3 1000 ^- = 0 Low -4.5 High +1.3 3. Bias Frequency Specification: 250 Kc Test: 253 Kc 4. Wow & Flutter Specification: .5% Peak to Peak Test: 5. Power Drain .5% Peak to Peak Specification: 5 amps Run WNFIDEN TIAL Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424A002000060019-5 CONFIDENI IAL 5. Power Drain (contd.) 6. Signal to Noise Specification: Test: Rewind 9 amps Amplifiers . 8 amps Start Forward Play 5 amps Forward Record 5.3 amps Unit Stopped Noise CH 1 .25 volts peak to peak CH 2 . 13 volts peak to peak CH3 .5 volts peak to peak Noise rms CH 1 -42 db CH 2 -43 db CH 3 -37 db Unit Running Noise rms IDENTIRL CH 1 -34 db CH 2 -37 db CH 3 -34 db Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424A002000060019-5 Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 vy~_vLev i ~~~ GOttFIDENTIAL Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 TEST REPORT ENVIRONMENTAL CONDITIONS Model MR-1. 25X1 1 i"EA'T TESTS 1, 1 Test on Circuit Cards Only 60 cycle frequency sub-system. AO-49 (3600 cps oscillator) connected to FD-] (frequency divider) for 60 cps output. Temperature Gain Remarks 70? F 0 db Ambient reference setting 120? F - 1 db Rising temperature - heat chamber 140? F -1, 5 db Rising temperature - heat chamber 150? F -2 db Rising temperature - heat chamber 150? F -3 db Stabilized temperature 15 mins, - heat chamber 1.2 Test on Entire Unit Removed from case to allow faster stabilization at temperatures. Temperature Operation Remarks 120 0 F Normal Drive motor comes to sync in normal time 125 0 F Normal Drive motor comes to sync in normal time 125? F Normal Runs sync speed through 1800 ft, reel of tape 125? F Normal Stabilized 15 mins.: then repeated 1800 ft. run Entire unit in case (to prevent frost condensation on components), Starter Drive Motor Temperature Motor Solenoids Runs Inc Remarks -40? F OK OK No No -20? F OK OK No No -0? F OK OK No No +20? F OK OK No No +300 F OK OK No No +32? F OK OK Yes No W ould not quite pull in +40? F OK OK Yes Yes N ormal operation CONFIDENTIAL Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 I Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5 Co 3 ROOM AM t31[E,NT 'rl-:sTs 3. 1 FrequencN Response Within specification, 3,2 OutLut Level Within specification: 3.3 Record Level Within specification, 3.4 50 h cps Record Formal, 3.5 (erational Check Normal operation. CONFIDEN IIAC 25X1 Sanitized Copy Approved for Release 2011/09/19: CIA-RDP78-03424AO02000060019-5