ENCLOSED IS OUR VERSION OF SECTION 7 OF THE PURCHASE DESCRIPTION THAT COVERS THE ACCEPTANCE TESTING FOR THE MODEL 1 UNIT.

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78-03642A001600040007-3
Release Decision: 
RIPPUB
Original Classification: 
C
Document Page Count: 
8
Document Creation Date: 
December 27, 2016
Document Release Date: 
September 18, 2012
Sequence Number: 
7
Case Number: 
Publication Date: 
June 29, 1960
Content Type: 
LETTER
File: 
AttachmentSize
PDF icon CIA-RDP78-03642A001600040007-3.pdf507.85 KB
Body: 
Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 Dear Sir: June 29, 1960 CONFIDENTIAL Enclosed is our version ofSection 7 of the Purchase Description that covers the acceptance testing for the Model 1 unit.) We would appreciate any comments which you or your associates might care to make with regard to the desCribed procedure. We shall be glad to submit copies of this section to ABW:mlm Enclosure In Triplicate if you so desire. 0111GIV$94 .5q 71- _2______ 05/6' DATE DATE /JuLiez) By 06-741#7 Of KR 1194 OPI 5-6 TYPE ?RIG COMP cuss prozs RUT REV REY CLASS 26 (6 RUTH! O DECL FigypitiN 77.26 TO ma 2-2- 'UT Byt,0;,6,,RS BY $a4 Me MT REASON 3 cL(3) CONFIDENTIAL Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 25X1 25X1 608-63 BOO 25X1 Declassified in Part- Sanitized Copy Approved forRelease2012/09/18 : CIA-RDP78-03642A001600040007-3 t ce/ CONFIDENTIAL (Section 7 of Purchase Description) Rejection 7.1 Functioning Tests Each Incinerator Assembly (Drawing No. 354-100) shall be subjected to separate functioning tests -prior to acceptance. Proper func- tioning of one Incinerator Assembly shall not constitute a basis for aver-all acceptance of the entire lot. Functioning tests shall be conducted in two parts: (1) cold air-flow tests, and (2) paper- burning test 7.1.1 Cold Air-Flow Tests Each Incinerator Assembly, with Blower (Drawing No. 354-437), shall be connected temporarily to an electrical outlet providing 220-volt, 60-cycle, 3-phase current. The Manometer shall be filled with water (with or without dye) and con- nected by the Rubber Tubing to the Pressure Tap Fitting at- tached to the Bottom Assembly Outer Shell (Drawing No. 35)4-103). The cold air-flow tests shall be made while the Incinerator Assembly is empty, in order (1) to check for leaks at the gasketed joints, and (2) to measure the plenum-chamber pressure, which is an indication of the over- all satisfactory condition of the flow passages such as the louvers in the Top Liner Assembly (Drawing No. 35)4-104), the Liner Middle Section Assembly (Drawing No. 354-105), and the Liner Bottom Section Assembly (Drawing No. 35)4-113); the CONFIDFNTIAL Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 Declassified in Part- Sanitized Copy Approved forRelease2012/09/18 : CIA-RDP78-03642A001600040007-3 -2- CONFIDENTIAL Nozzles (Drawing Nos. 354-333, 35)4-334, and 354-335); and the Flexible Duct (Drawing No. 354-434) and the damper, comprised of the Damper Housing Assembly (Drawing No. 354-209), the Butterfly Assembly (Drawing No. 354-202), the Damper Shaft (Drawing No. 354-314), and a few minor parts. To check for leaks, the Blower shall be turned on and the damper opened by moving the Handle Assembly (Drawing No. 354-112) to the "Operating" position* on the Control Plate (Drawing No. 354-306). The inspector shall then check for air leaks at each of the gasketed joints of the Incinerator Assembly. Initially, the inspector shall check for air leakage by passing his bare hand along each gasketed joint. Leakage thus detected shall be judged excessive if the flame from a lighted "paper book" match is extinguished when held within al-inch distance of the source of leakage. Excessive leakage of air at any of the gasketed joints shall be corrected by appropriate measures before the cold air- flow testing is continued. To measure the plenum-chamber pressure, the Blower shall be turned on and the damper set at the "Operating" position as described above. Under these conditions, the internal air pressure in the lower plenum chamber, as indicated by the Manometer, shall be between 6.0 and 7.0 *The "Operating" position corresponds to the fifth notch. The first notch represents the "Closed" position; the second notch, "1/4 Open"; the third notch, "1/2 Open"; and the fourth notch "3/4 Open". co TIAL Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 \nip/ -3- CONFIDENTIAL inches of water. If the pressure is not within this range, the inspector shall examine all air-flow passages, as described above, to determine the cause. Any errors or defects stemming from the manufacture of the Incinerator Assembly that contribute to internal pressures outside the range of 6.0 to 7.0 inches of water shall be corrected by the manufacturer. The measurement of the plenum-chamber pressure shall then be re-run before proceeding with the paper-burning test. 7.1.2 Luer-Burning Test The paper-burning test shall consist of burning 500 pounds of selected paper during a period of 2 hours. Prior to the burning test the Thermocouple shall be inserted into the fitting on the stack; the bead of the Thermocouple shall be located at the center of the stack. The Temperature-Indica- ting Instrument (Sim-Ply-Trol) shall then be properly con- nected to the Thermocouple with the Extension Lead Wire. A supply of reasonably dry paper shall be obtained and used for the burning test. Typical paper from discarded of- fice files, such as Bond and onionskin typing paper, file cards, and file folders (excluding newspapers or telephone books) shall be considered suitable. At the beginning of the burning test, the Door Assembly (Drawing No. 354-114) shall be opened and 50 pounds of mixed CONFIDENTIAL Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 Declassified in Part- Sanitized Copy Approved forRelease2012/09/18 : CIA-RDP78-03642A00116F0/0040007-3 Na NTIAL .1. I papers shall shall be loaded into the Incinerator Assembly. A few crumpled sheets of paper shall be ignited and scattered over the paper charged; the Door Assembly shall be closed and the Blower turned on. During the first 3 to 5 minutes, the Handle Assembly shall be advanced gradually from the "Closed" to the "Operating" position on the Control Plate while the ? inspector observes the progress of ignition. When ignition is well established, intermittent feeding of 15-pound batches of paper shall be started. Each of the thirty 15-pound batches shall be fed by (1) quickly moving the Handle As- sembly to the "Closed" position; (2) opening the Door Assembly; (3) charging the paper; (4) closing the Door Assembly; and (5) moving the Handle Assembly quickly to the "1/2 Open" position (third notch), and then gradually to the "Operating" position (fifth notch), so as to avoid suddenly reaching ex- cessive stack-gas temperatures above 1800 F. Successive batches shall be fed at intervals of about 3 minutes, or less, depending on the rate of burning; the pile of paper in the incinerator shall not be allowed to decrease below the initial level (corresponding to the first 50 pounds) or to increase above a level approximately 6 inches below the bottom Of the loading opening in the Liner Middle Section Assembly. Near the end of the burning test, the slow burning residue shall be stirred once by manual poking, to obtain more rapid and complete burnout. If observation indicates that DENTAL Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 ? , Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 44, 4_ ? - -5- CONFIDENTIAL burning has stopped, any unburned paper or char shall be re- ignited Once and the burning continued at low air flow (with the Handle Assembly at the "1/4 Open" or "1/2 Open" position) for final burnout. 7.2 Results of the burning test shall be considered satisfactory by the inspector and each Incinerator Assembly shall be acceptable if the following conditions are achieved: (1) Incineration of 500 pounds of paper shall be completed in 2 hours. (2) The residual charred paper, excluding the ash which remains at the end of the 2-hour test period, shall not exceed 1-1/2 pounds in weight. (3) Any pieces of charred or raw paper carried out in the stack gases shall be no larger than that which would pass freely through the mesh openings of the Basket Assembly (Drawing No. 354-111). (4) All movable parts associated with the loading door, that is, with the Door Assembly, Frame Assembly (Draw- ing No. 354-207)) and Latch Assembly (Drawing No. 354-215), and with the damper, that is, with the Damper Housing Assembly) the Butterfly Assembly, and the Damper Shaft, shall function properly, as intended. If any one of the above conditions is not met during the test, the malfunction which, is attributable to improper 'Uld:NTt , Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 CONFIDENT 4\ -6- fabrication, assembly, and/or workmanship shall form the basis for rejection. Rejection shall not preclude the manufacturer from correcting the conditions which form the basis of rejection, and from reworking a rejected part to remedy such defects for resubmission to inspection and test. However, all units and parts so reworked shall be so indicated to the inspector. Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3 -411.1i)L4 TWIN AIR orr Krum 11(434 I NG 00011 CON Fitr\M 2"` ?411 ra. Declassified in Part - Sanitized Copy Approved for Release 2012/09/18: CIA-RDP78-03642A001600040007-3