HEADQUARTERS POWER TESTING SCHEDULE

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78-04722A000200010010-4
Release Decision: 
RIFPUB
Original Classification: 
S
Document Page Count: 
2
Document Creation Date: 
December 9, 2016
Document Release Date: 
June 8, 2000
Sequence Number: 
10
Case Number: 
Content Type: 
CHART
File: 
AttachmentSize
PDF icon CIA-RDP78-04722A000200010010-4.pdf193.09 KB
Body: 
crT Approved For. Release 2000/08/28 : CIA-RDP78-04722A000200010010-4 HEADQUARTERS POWER TESTING SCHEDULE POWER INTERRUPTION POWER SOURCE JANUARY, JULY ALL OTHER MONTHS- Frantic 10 seconds at None 1900 hours. Critical 90 to_ 120 seconds None at 1900 hours. Commercial Power total from 1900 to 2200 hours. NOR TH HALF OF BUILDING POWER INTERRUPTION POWER SOURCE JANUARY, JULY ALL OTHE MONTHS Frantic ~.. 10 seconds at None 1900 hours. Critical 90 to 120 seconds None at 1900 hours. Emergency Approximately 15-minute outage starting at 1900 hours. Commercial Power Total from 1900.to 2200 hours. Formerly the 30 kw. uninterrupted power source. Presently 250 kw., 10-second response, automatic-start generator located within the Headquarters Building and backing up the following loads: b. Select equipment for the Office of Communications. . Select equipment for the Office of Security. Select equipment in the 7D 25 - 7E 35 area. =' Approved For Release 2000/08/28 : CIA-RDP78-04722A000200010010-4 backing up the following loads: Approved for Release. 2000/08/28 : CIA-RDP78-04722AO0020001001.0-4 2500 kw. 90- to 120-second response, automatic-start generator located adjacent to the powerhouse and a. All loads located in the south half of the Building which previously were on emergency. power; i. e. , all loads in the south half of the Building which were backed up by the two each 2000 kw. manual-start generators are now backed tip by the 2500 kw. automatic-start generator. b. Select loads in the. north half of the Building including all telephones, all KY-3's-and the area between 7D 25 and 7E 35. Emergency Power: Two each 2000 kw. manual-start, l5-minute respo-nse'generators located in the powerhouse-and backing up the following loads: All emergency loads in the north end of the Building; i. e., no change -- all loads in the north end of the Building previously on emergency power (two each 2000 kw. 's) are still on emer- gency power. There is no emergency power in the south half of the Building during the test. In an actual outage, however, emergency power can be switched, as necessary, from the north half of the '.: Building to the south half of the Building. Approved For Release 2000/08/28: CIA-RDP78-04722A000200010010-4