PROPOSAL MODIFICATIONS

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04747A000100150035-7
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
3
Document Creation Date: 
December 28, 2016
Document Release Date: 
March 1, 2000
Sequence Number: 
35
Case Number: 
Publication Date: 
January 5, 1962
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP78B04747A000100150035-7.pdf133.2 KB
Body: 
Approved For Release 2000/05/10 : CIA-RDP78B04747A000100150035-7 B A U S C H & L O M B I N C O R P O R A T E D R 0 C H E S T E R 2, N E W Y 0 R K O.i` OSAL W/I 1CA 3._XO Higher Magnifications - Magnifications up to 50X can .bey provided by supplying two additional lens ea. The short focal lengths required indicate that separate bellows- Ions assomblies will be required. The shorter focal lengths have an inherent critical fooue adjustment re- quirement that will be beat solved by providing a fine rack and pinion mechanism for each lens. Hsoonded Lonaes and Data 2.25 inch focal length,, 1X to 30X and 1.33 inch focal longth., 27X to 53X. The higher magnification also dictate a higher illumina- tion level (approximately 16 times) to maintain a reason- able image brightness. It is almost certain thet no one Illumination system will, be capable of providing the high level illumination required and still be coMatible for use at the lowest magnifications* Interchangeable light sources appear the most practical solution. The high level light source will require more extensive heat control design to maintain film safety, a 25?F rise over an BOO? bent will be a desi goal. Film Spools -? Brackets will be added to the top rear of the instrument base,,, one on either side of the projector head support members. The brackets will be adjustable end accept any film width from 70M to 9.1/2 inches on spools up to 7-5/8 inch diameter. Projected Grid ..An auxiliary film pressure plate con- taining a Mid pattern will be supplied. This plate can be placed in the projection plane with the film as desired, The grid can be installed as a semi-permanent part of the projector or maintained as a loose accessory. A pattern of squares showing the field of view for the limiting magnifications of each range will be included in the stage glass. Approved For Release 2000/05/10 : CIA-RDP78B04747A000100150035-7 Approved For Release 2000/05/10 : CIA-RDP78B04747A000100150035-7 B A U S C H & L O M B I N C O R P O R A T E D I.. Portability - The Instrument will be for one man portability, ovided with casters The table height of .0" is a minims defined by mirror size and travel, The instrument base dimensions are defined by the same elements. Access is provided to three sides of the working stir face for a standing or stool seated operator, The instrument top will be square end rigid enough for a drafting machine, y' !s 1962 Approved For Release 2000/05/10 : CIA-RDP78B04747A000100150035-7 25X1A Approved For Release 2000/05/10 : CIA-RDP78BO4747A000100150035-7 Approved For Release 2000/05/10 : CIA-RDP78BO4747A000100150035-7