INSTALLATION ENGINEERING

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04747A000300010022-4
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
2
Document Creation Date: 
December 28, 2016
Document Release Date: 
October 5, 2001
Sequence Number: 
22
Case Number: 
Content Type: 
FORM
File: 
AttachmentSize
PDF icon CIA-RDP78B04747A000300010022-4.pdf82.76 KB
Body: 
Approved For Relea2001/11/19 : CIA-RDP78B04747A000010022-4 INSTALLATION ENGINEERING I. INSTRUMENT / 't C4 A. Name 14,tace-sse r B. Manufacturer C. Contract Numb_ 7e II. PHYSICAL FEATURES A. Number of Component Parts B. Dimensions of the Largest Component Part: Length Ft. In. Height Ft. Width Ft. In. C. Weight of Largest Component Part D. Total Weight of Instrument E. Overall Dimensions Assembled: Length 8 t. 0 In. Height 5 Ft. 7 In. Width Ft. C In. .14 F. Type of Base of Mount: Flat Three Point Suspension Four Point Suspension X G. Does Instrument have built-in mobility? No H. Is the instrument particularly sensitive to vibration? Yes I. Are any special or unusual tools or fixtures necessary or advisable for the installation or maintenance of this equipment? No III. UTILITIES A. Electrical: AC DC. Voltage 220 Volts + Volts Current 40 Amps Frequency 60 cps Nr. of phases Single Nr. of wires 3 + ground Power required by equipment Watts Watts Type of outlet required: Two Prong , Three Prong plus grounsfell Twist Lock , Permanent Installation Should the equipment be shielded, either from external electro- magnetic signals, or to prevent interference with other equipment? Declass Review by NIMA/DOD Approved For Release 2001/11/19 : CIA-RDP78BO4747A000300010022-4 Filtered 78 OF + 2 OF Particle size and count per unit volume. 10 Microns Type of pipe required: Galvanized Stainless Steel Is floor drain required? Diameter of drain 4" Plastic drain Approved For Rel 2001/11/19: CIA-RDP78B04747A00%00010022-4 B. Air Conditioning: Room temperature 720 Humidity Normal Output of Instrument ? BTU/Hr- If air must be filtered, what is maximum permissible particle size in microns? Normal Lab Conditions What particle count? particles per cubic foot. Direct connection to instrument? Yes No If yes to above, what is the desired air temperature to instrument? Should discharged air be ducted separately? yes Is discharged air noxious? No toxic'? No Connector size to instrument Tempered OF + Deionized OF + Copper X Tap OF + OF Water pressure Normal Type of water desired: C. Plumbing: Is water required for the instrument? Yes X No D. Compressed Air: Diameter of connectors N.A. PSI CFM E. Vacuum: Is vacuum required? Vacuum required No meters)of Hq Displacement Plastic Yes X No Galvanized drain Glass drain Type of connectors Water free? Oil free? inches milli- In the event additional space is required for environmental conditions or utilities not mentioned above, use the reverse side of this form. 20" work space required above instrument 36" work space required on each side & end. 2 Approved For Release 2001/11/19 : CIA-RDP78BO4747A000300010022-4