SYSTEM CHECKS - INTERFEROMETER OF 405B

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04747A001500030019-3
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
8
Document Creation Date: 
December 28, 2016
Document Release Date: 
January 29, 2002
Sequence Number: 
19
Case Number: 
Content Type: 
LIST
File: 
AttachmentSize
PDF icon CIA-RDP78B04747A001500030019-3.pdf157.81 KB
Body: 
0 0 Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 D R A F T D R A F T SYSTEM CHECKS - INTERFEROMETER 71W S I3 V,O,IVM 1) System 9 tine 11N,, 2) Ready light time and Bias and signal at this time. 3) Bias and signal 15 min. after ready light is on 4) Tank Temperature - r temperature cycle time (heater) 5) Bias swing from heater to heater an, 6) Drift Compensator range and ooeration_ 8) Repeatability at ready light on time) at 12:00, at 2:00, and 4:30. Bias and signal at this time.i 9) Any errd:r greater than 5 counts see g.,~i.~-r, i ~?~~~~ 10, IV and 30 min. steps. 405 1) Check range 4-1/4" .~'t"- 2) Focus over range g and Y 3) Pointing Accuracy 4) Console check vacJsignal DECLASS REVIEW by NIMA/DOD spot, 14gtspot, color filters, etc. Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 Approved For Release 2002/06/17 : CIA-RDP78B04747A001500030019-3 D R A F T OPERATING PROCEDURE Recommended Schedule Daily, After Turn On 9 1. Turn Power On 2. Allow system to warm up for approximately 45 minutes to one hour, (and when the ready light is on). 3. To set Automatic Compensator circuit on, the following procedure is to be followed: A. Set X Axis: 1. Push X axis drive to the "Left" until the limit switch stop motion. 2. Put on X auto-compensator switch. 3. Push X drive switch to "Right" for approximately 1" (approximately 20 seconds) and immediately reverse back to the "Left" limit. 4. Switch off X axis auto-compensator switch when table is still coasting close or at the limit of travel (Left). Approved For Release 2002/06/17 : CIA-RDP78B04747A001500030019-3 ?(2) Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 D R A F T D R A F T 49 0 1. Push Y axis drive to the "In" until the limit switch stop motion. 2. Put on Y auto-compensator switch. 3. Push Y drive switch to "Out" for approximately 1" (approximately 20 seconds) and immediates reverse back to the "In" limit. 4. Switch off Y axis auto-compensator switch when table is still coasting close or at the limit or travel (In). 4. System is now ready for use. Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 Approved For Release 2002/06/17 : CIA-RDP78B04747A001500030019-3 D R A F T D R A F T D R A F T (ONCE/WEEK) First step - per daily check list 2. Check f - e - should be IS - ~J 3. Check water level by removing cover and observing water level, top up if necessary. 4. X Axis by voltageL level checks. ~ a l,~t ?~ 4%717[ rr Lam' c LtiF/41.~ Y rr C7 4 ' f ' 7VI L~ Ile,; All / Place D.C. Meter bias 8V + .5V 0 B [if c, 5;"- ~' EDO If any of these is not in specification, see adjustment procedure; STATINTL Check 1'v 10.5 + lv 1, e 10.5 + 1V 5. Repeat 4) for Y axis Approved For Release 2002/06/17 : CIA-RDP78B04747A001500030019-3 Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 6. Check repeatability a) Place grid on platen b) Apply vacuum c. Set machine to center of travel with index mark of grid at the center d) Zero X and Y counters e) Traverse to one edge 2 1/8" from center and go around table as indicated. All paths 2 1/8" from center. f) Return to center index mark. g) Read counters - both X and Y should read zero + 8 counts. i Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 D R 2'A prrved For Release 2002/06/17 : CIA-RDP78B04747A001500030019-3 ADJUSTMENT PROCEDURE XOnce/week if required, or biweekly check) 1. If checks showed that cemr*e-ln phases A, B. C, and/or 7,1 `j4Pat.~/, Schmidtt'are out of tolerance, ?e lew the following adjustment procedure: 9 2. Read and record biases with VOM and signal peak to peak with oscilloscope. Run motor or rotate handwheel re m,, it Table must saan within 1/s" of IN position of Y and "left" position of X. X Axis Signal Bias ? Y Axis Should Be 1.8V ? 0.2V 8V ? 0.1V Same as X 3. Operate one axis at a time. Z>iG Z.j/` vo I ~s A. Adjust Signal on each channel to 1.8 ? 0.2 watts. y~ If any potentiometer goes out of range, adjust the is High voltage common potentiometer on the Digitizer I-or` Apoleabe 2002/06/17: CIA-RDP78B04747A001500030019-3 lv) 6/72 je Co, r,7c e rte " / B. Adjust biases to 8.0 ? 0.1 w-att-s If any potentiometer goes out of range, adjust them. High voltage common potentiometer on the Digitizer for Travel. /.S ~7FPrti6~6 Y der this the signalja~ will require re-adjustment. "r .kI br"~ s C. Unplug P114 from PC card which removes Automatic Compensator. Adjust front and rear Schmidt triggers to 10.5 ? 0.2 volts using a VOM D. Adjust 0fo Drift Compensator. Plug VOM into test jack on Auto Compensator Assembly and adjust T t R A Repeat from point B and R E. Replug pendant cable from card. Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 2. 4. Repeat for other axis if necessary. Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3 FORM 10 1 REPLACES FORM 10-101 Approved For Release 2002/06/17 : CIA-RDP78BO4747AO01500030019-3