INSTALLATION ENGINEERING

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04747A001600020042-7
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
3
Document Creation Date: 
December 28, 2016
Document Release Date: 
April 20, 2000
Sequence Number: 
42
Case Number: 
Content Type: 
STATEMENT
File: 
AttachmentSize
PDF icon CIA-RDP78B04747A001600020042-7.pdf137.64 KB
Body: 
proved For Relea,~e 2000/06/07 :CIA-RDP78B0474~-001600020042-7 INSTALLATION ENGLNEERING Declass Review, NIMA/DoD L. INSTRUMENT A. Name D' i I oo dinato ra h B. Manufacturer C. Contract Numbe ~'t/~ Yet - /~~C G? II. PHYSICAL FEATURES STATOTHR A. Number of Compone~ a~~~gtts 4 major parts *B. Dimensions of the Component Part: Length 7 Ft. 5 In. Height 0 Ft. 7 In. Width ~_Ft. 9 1 $ In. C. Weight of Largest Component Part '300 D. Total Weight of Instrument `'500 E. Overall Dimensions Assembled Length ~^F-t. 11~ In. Height ~_Ft. 5 5 $ In. Width ~_Ft. 7~ In. F. Type of Base of Mount: Five Flat Three Point Suspension ~6L[r'Point Suspension x G. Does Instrument have built-in mobility? No H. Is the instrument particularly sensitive to vibration? N o I. Are any special or unusual tools or fixtures necessary or adviseable for the installation or maintenance of this equipment? N o III. ~ UTILITIES A. Electrical: AC DC Voltage 208 Volts + Volts 0 Current 62~Amps ~ -~- Frequency ~_cps Nr. of phases $ Nr. of wires 4 Power required by equipment 22 ~ +~ KVA 0 Watts Type of outlet required: Two Prong , Three Prong Twist Lock , Permanent Installation x Should the equipment be shielded, either from external electro- magnetic signals, or to prevent interference with. other equipment? i in owe lines At inte als cir uits cart in u to 150 am eres DC at 75 volts will a opened by conventional DC contactors. Af the same time an AC connector will interrupt a 15 KVA,208,3 phase load. * Dimension of Largest Component part: Length 7= 5" Width 5'-1'1 5/8" Weight 900 Height 1'-9 13/16" Approved For Release 2000/06/07 :CIA-RDP78B04747A001600020042-7 . ~p~~ov~ea rorxeie ~uuuiubkur ? ~:i~-r~~~~z~~r~~~p1uu41-r it conditionin or room, oorri em e a r B. Air Conditioning:for instrument n,.,,m +?mra,..n+?r~ Humidity i lo' ~- Output of Instrument 30,000 BTU~Hr. not i erate to room If air must be filtered, what is maximum permissible particle size in microns? 3 What particle .count? Zero Magnetic particles per cubic foot. ' Direct connection to instrument? Xes x No If yes to above//, what' is the desired air temperature to instrument? 42oF CPSD~~M~NJk (as-~ ~~.,o~c3}, !}~i47~oC'fYti~e~1~C~~ _ Should discharged air be ducted separately? Yes Is discharged air noxious? N o toxic? N o Connector size to instrument Eauivalent to five 3" diam hoses C. Plumbing: Is water required for the instrument? Yes No x Water pressure Type of water desired: Tap of + Tempered Deionized _ Filtered unit volume. Flow in GPM of + ?F Type of pipe required: Galvanized Stainless Steil Is floor drain required? Diameter of drain Plastic drain ?F Particle size and count per Copper Plastic Yes Galvanized drain Glass drain D. Compressed Air: None Diameter of connectors Type of connectors PSI Water free? CFM Oil free? E? Vacuum: Is vacuum required? Vacuum required ~ A PSIA or (inches milli- meters~of Hq Displacement _ $0 CFM In the event additional space is required for environmental conditions or utilities not mentioned above, use the reverse side of this form. 2 Yes X No Approved For Release 2000/06/07 :CIA-RDP78B04747A001600020042-7 Approved For Release 2000/06/07 :CIA-RDP78B04747A001600020042-7 ~~~ ~~.~r `v 5s Approved For ~telease X000/06/07 :CIA-RDP78~304747A001600020042-7