L. INSTRUMENT
A. Name D' i I oo dinato ra h
B. Manufacturer
C. Contract Numbe ~'t/~ Yet - /~~C G?
II. PHYSICAL FEATURES STATOTHR
A. Number of Compone~ a~~~gtts 4 major parts
*B. Dimensions of the Component Part:
Length 7 Ft. 5 In. Height 0 Ft. 7 In.
Width ~_Ft. 9 1 $ In.
C. Weight of Largest Component Part '300
D. Total Weight of Instrument `'500
E. Overall Dimensions Assembled
Length ~^F-t. 11~ In. Height ~_Ft. 5 5 $ In.
Width ~_Ft. 7~ In.
F. Type of Base of Mount: Five
Flat Three Point Suspension ~6L[r'Point Suspension x
G. Does Instrument have built-in mobility? No
H. Is the instrument particularly sensitive to vibration? N o
I. Are any special or unusual tools or fixtures necessary or adviseable
for the installation or maintenance of this equipment? N o
III. ~ UTILITIES
A. Electrical: AC DC
Voltage 208 Volts + Volts 0
Current 62~Amps ~ -~-
Frequency ~_cps
Nr. of phases $
Nr. of wires 4
Power required by
equipment 22 ~ +~ KVA 0 Watts
Type of outlet required: Two Prong , Three Prong
Twist Lock , Permanent Installation x
Should the equipment be shielded, either from external electro-
magnetic signals, or to prevent interference with. other equipment?
i in owe lines At inte als cir uits cart in u to 150 am eres DC at
75 volts will a opened by conventional DC contactors. Af the same time an AC
connector will interrupt a 15 KVA,208,3 phase load.
* Dimension of Largest Component part:
Length 7= 5"
Width 5'-1'1 5/8"
Weight 900
Height 1'-9 13/16"
Approved For Release 2000/06/07 :CIA-RDP78B04747A001600020042-7
. ~p~~ov~ea rorxeie ~uuuiubkur ? ~:i~-r~~~~z~~r~~~p1uu41-r
it conditionin or room, oorri em e a r
B. Air Conditioning:for instrument
n,.,,m +?mra,..n+?r~ Humidity i lo' ~-
Output of Instrument 30,000
BTU~Hr. not i erate to room
If air must be filtered, what is maximum permissible particle size
in microns? 3 What particle .count? Zero Magnetic
particles per cubic foot. '
Direct connection to instrument? Xes x No
If yes to above//, what' is the desired air temperature to instrument?
42oF CPSD~~M~NJk (as-~ ~~.,o~c3}, !}~i47~oC'fYti~e~1~C~~ _
Should discharged air be ducted separately? Yes
Is discharged air noxious? N o toxic? N o
Connector size to instrument Eauivalent to five 3" diam hoses
C. Plumbing:
Is water required for the instrument? Yes No x
Water pressure
Type of water desired:
Tap of +
Tempered
Deionized _
Filtered
unit volume.
Flow in GPM
of
+ ?F
Type of pipe required:
Galvanized
Stainless Steil
Is floor drain required?
Diameter of drain
Plastic drain
?F Particle size and count per
Copper
Plastic
Yes
Galvanized drain
Glass drain
D. Compressed Air: None
Diameter of connectors Type of connectors
PSI Water free?
CFM Oil free?
E? Vacuum:
Is vacuum required?
Vacuum required ~ A PSIA or (inches milli-
meters~of Hq
Displacement _ $0 CFM
In the event additional space is required for environmental conditions
or utilities not mentioned above, use the reverse side of this form.
2
Yes X No
Approved For Release 2000/06/07 :CIA-RDP78B04747A001600020042-7