INSTALLATION ENGINEERING DATA
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP78B04747A002400050042-5
Release Decision:
RIPPUB
Original Classification:
K
Document Page Count:
2
Document Creation Date:
December 28, 2016
Document Release Date:
June 3, 2002
Sequence Number:
42
Case Number:
Publication Date:
May 19, 1967
Content Type:
SUMMARY
File:
Attachment | Size |
---|---|
![]() | 59.97 KB |
Body:
Approved For Rase 2002/08/06: CIA-RDP78BO4747A
Date Form Completed:
INSTALLATION ENGINEERING DATA
A. Name of Instrumenti
B. Manufacture
C. Contract Number:
D. Delivery Date: 3 June 1967.
Wide Film Processor.
7
II. PHYSICAL FEATURES
A. Sub-assemblies: Not applicable.
B. Assembled instrument:
1 . Number of major components: 1.
2. Total floor space required after assembly, including maintenance
access space: 7 ft. 4 in. high x 9 ft. 6 in. wide x 17 ft. 0 in.
deep.
3. Actual unit size: 4 ft. 6 in. high x 3 ft. 6 in. wide x 11 ft. bng.
C. Type of base of mount: Casters; 4-point suspension.
D. Does the instrument have built-in mobility? Yes.
E. Is the instrument particularly sensitive to vibration. No.
Will the instrument generate vibration? No.
F. Are any special or unusual tools or fixtures necessary or adviseable
for the installation or the maintenance of this instrument? No.
1., Voltage: 110/220 volts, AC.
2. Current: 100 Amps/phase.
3. Frequency: 60 cps.
4. Nr. of phases: 2 Ph.
5. Nr. of wires: 4.
6. Type of outlet: Twist lock.
7. Should the instrument be shielded, either from external electro-
magnetic signals or to prevent interference with other equipment?
No.
Declass Review by
NIMA/DOD
Approved For Release 2002/08/06 : CIA-RDP78BO4747AO02400050042-5
19 May 1967
STAT
STAT
Approved For'R4Iease 2002/08/06: CIA-RDP78B047402400050042-5
B. Air Conditioning:
1 . Desired environment: Room air temperature of 70? F / 750 F
and relative humidity of 40% , 45%.
2. Input air: Is a direct connection necessary? No.
3. Output air: Is a direct connection to the return air duct
necessary? No.
C. Plumbing:
1. Is water required? Yes.
2. Type of water required: Tap, 68? F / 70? F. If filtered, give
maximum permissible particle size in microns and the maximum
permissible count: 10 microns.
3. Pipe required: Copper, size I"; type of connector, hose.
4. Are any chemical solutions used in the device? Yes.
D. Compressed air:
Is compressed air required? No.
E. Vacuum:
Is vacuum required? No.
F. Peripheral Devices:
Will the instrument be connected to any peripheral devices such as
a computer or data input or data output device? No.
STAT
Approved For Release 2002/08/06 : CIA-RDP78B04747A002400050042-5