LETTER (Sanitized)

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A000100020006-4
Release Decision: 
RIPPUB
Original Classification: 
C
Document Page Count: 
4
Document Creation Date: 
December 28, 2016
Document Release Date: 
April 24, 2012
Sequence Number: 
6
Case Number: 
Publication Date: 
October 2, 1964
Content Type: 
LETTER
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A000100020006-4.pdf163.92 KB
Body: 
Declassified in Part - Sanitized Copy Approved for Release 2012/04/24: CIA-RDP78BO477OA000100020006-4 October 2, 1964. Arlington, Virginia 22209 Roaslyn Station Gentlemen: Bausch & Lomb is pleased to submit for your evaluation a Cost and Technical Proposal for the design and manufacture of one (1) or two (2) pair of Low Power Wide Field Objectives for use with the Bausch & Lomb High Power Stereoviewer. Copies of our Technical Proposal are enclosed, as are copies of an outline drawing of the proposed objective, A fixed .)rice contract is anticipated. Our Cost Analysis is included as Attachment A. Delivery of the end item is estimated at within 12 weeks after- authorization to proceed. If you have any questions concerning this proposal, please contact the writer directly. GJJ: by o ogramme r c contracts Section Declassified in Part - Sanitized Copy Approved for Release 2012/04/24: CIA-RDP78BO477OA000100020006-4 Declassified in Part - Sanitized Copy Approved for Release 2012/04/24: CIA-RDP78BO477OA000100020006-4 Declassified in Part - Sanitized Copy Approved for Release 2012/04/24: CIA-RDP78BO477OA000100020006-4 Declassified in Part - Sanitized Copy Approved for Release 2012/04/24: CIA-RDP78BO477OA000100020006-4 B&L 8334 TECHNICAL DESCRIPTION and DESIGN OBJECTIVES for PROTOTYPES of a BAUSCH & LOMB WIDE FIELD OBJECTIVE This lens is a low magnification, wide field microscope objective. It is approximately parfocal with the higher magnification objectives used with the Bausch & Lomb Dyna- Zoom Laboratory Microscope. This objective may be used with the four position nosepiece without interfering with the other objectives. The real field of a microscope is equal to the field of the eyepiece divided by the magnification of the objective. The only way to get a significant increase in field is to lower the magnification of the objective. Lower magnifica- tion necessarily means increased working distance and below magnifications of approximately 3.5X the objectives cease to be parfocal. The objective lens covered by this description has a prism cluster in the lower conjugate that folds up the optical path enabling the lens to have a shoulder-to-object distance the same as that of the other lenses used on the DynaZoom Microscope. This prism cluster does not invert or revert the image. The nominal magnification of this lens , is 1.3X. The field depends on the eyepiece. With the Bausch & Lomb lOX Wide Field Eyepiece, Catalog Number 31-05-60, the real field is approximately 14.Omm. No resolution requirement. is specified for the prototype lot since the primary objective is a wider field for initial location of areas of interest. Specifications for follow-on quantities will be determined after evaluation of the prototype. BAUSCH & LOMB INCORPORATED Rochester, N.Y. 14602 September , 1964 Declassified in Part - Sanitized Copy Approved for Release 2012/04/24: CIA-RDP78BO477OA000100020006-4