Approved For Release 2006/08/31 : CIA-RDP78BO477OA001100060006-9 SECRET Monthly Report SUBJECT: recision Enlarger Prototype (BPE) Operational Improvements and Maintenance TASK/PROBLEM 1. Provide photographic enlarger maintenance at the customer's facility for one Precision Enlarger (BPE) and three* 10-20-1+OX Enlargers. DISCUSSION 2. Contractor personnel visited the customer's facility during the week beginning 31 March 1969 to perform six-month preventive maintenance (PM) on the BPE, and two-month PM on four* 10-20-1+OX Enlargers. (See check lists attached indicating the work performed.) 3. The six month PM on the BPE included a photographic checkout of the lens assemblies. During this checkout, the "H" lens-focus finding did not agree with the focus setting suggested on the drum scroll (a difference of 5 digits). As a result, this lens was returned to the factory for checkout. In addition, six "X" coordinate display lamps (yellow base) were replaced with longer life lamps (green base). The lamp problem is currently under investigation by the contractor and the vendor (Theta Corp). 4. The two-month PM on the four* 10-20-40X Enlargers included the following necessary adjustments and repairs: a. Serial No. 101: "X" coordinate counter was inoperative; the customer states that an order has been placed for a new counter. b. Serial No. 119: "Y" coordinate counter was repaired and adjusted for proper operation. c. Serial No. 113: LOX condenser (lens) piano glass was replaced. * Although the Task/Problem specifies preventive maintenance on three 10-20-1+0X Enlargers, the contractor regularly services four enlargers on the basis of the customer's verbal request. The customer has stated that he does not consider it necessary to revise PAR 21+9 at this time. ]ec1 ss Fk viey/ by F\1 ! -1- GROUP 1 SECRET EXCLUDED FROM AUTOMATIC DOWNGRADING AND DECLASSIFICATION Approved For Release 2006/08/31 : CIA-RDP78 04770A001 100060006- Approved For Release 2006/08/31 : CIA-RDP78B04770A001100060006-9 SECRET PAR 249 30 Apr 69 PLANNED ACTIVITY 5. Contractor personnel will visit the customer's facility during the week beginning 5 May 1969 to perform the 1-month PM on the BPE. GROUP 1 SECRET EXCLUDED FROM AUTOMATIC DOWNGRADING AND DECLASSIFICATION Approved For Release 2006/08/31 : CIA-RDP78B04770A001100060006-9 Approved For Release 2006/08/31 : CIA-RDP78B04770A001100060006-9 SECRET PAR 219 30 Apr 69 PREVENTIVE MAINTENANCE SCHEDULE CHECK LIST 0 Assigned ro Date 1 Apr 69 Machine Serial No. 001 (Prototype) 25X1 It?m Description Item Description Daily Interval I Check the four indicator lamps on the sub-control panel. 2.1 Check closed-negative-gate interlock. 2.2 Check interlock that causes vertical transport slow speed. / 2.3 Check interlock that disables negative transport after fluid injection. 2.4 Check operation of microswitch that functions when manual-film-movement knob is pushed in. / 3.1 Check the indicator lamps for the two attenuator banks of the easel photometer. 3.2 Check the meter scale illuminator lamp of the easel photometer. 3.3 Check the antifatigue lamp in photo- multiplier tube housing. 4 Clean the glass plates of the negative gate. 1 Vacuum-clean the enlarger. 2 Check, and if necessary, clean the objective lenses and all glass filters. 3 Vacuum-clean the front surface of the easel. V 4 Check the fiber optics for broken 1 fibers. 1 Wax the steel rails of the lens ramp and of the easel. 2 Install new air filter in lamphouse. 3 Clean the nylon brushes of the fluid removal system. 7 4 Check all tubing and hoses for cracks and air leakage. 5 Check and, if necessary, clean the lenses of the condenser lens assemblies. 1.1 Make a photographic check on all six matching sets of objective and condenser lens assemblies. 1.2 Be sure that film is tracking properly in both directions on the negative transport system. Checked byl Check the timing belts of the film transport system, of the vertical drive system, and of the easel drive assembly for wear. I_ Date 2 Apr241 "H" lens focus differs from scroll by 5 digits; returned to factory for checkout. In addition, six yellow-base "X" coordinate display lamps were replaced with green-base (longer life) lamps. IEXCLUDED GROUP 1 -3- FROM AUTOMATIC DOWNGRADING SECRET AND DECLASSIFICATION Approved For Release 2006/08/31 : CIA-RDP78B04770A001100060006-9 Approved For Release 2006/08/31 : CIA-RDP78BO477OA001100060006-9 SECRET PREVENTIVE MAINTENANCE SCHEDULE CHECK LIST TWO-MONTH INTERVAL PRECISION ENLARGER, 10-20-4oX PAR 249 30 Apr 69 Assigned To: 25X1 Date: 3 Apr 69 Machine Serial No. 101 / Item D...:rip ion / Item Description 1 Film Transport, 8 Vacuum Pump Assembly / 1.1 Static Removal Unit 8.1 Hoses and Couplings 1.2 Guide Roller Flanges 8.2 Pump / 1.3 Air Knives 8.3 Oil Level / 1.4 Belts and Pulleys / 9 Lamp House Assembly / 1.5 Lubricate Bearings / 9.1 Housing 2 Easel and Stencil Assembly / 9.2 Filter (Photographic) 2.1 Easel / 9.3 Light Leaks / 2.2 Air Pressure System / 9.4 Lamp House Blower 10 Immersion System / 3.1 Glass / 10.1 Ejectors V 3.2 Lamps / 10.2 Hoses and Couplings 4 Negative Gate Interlock / 10.3 Blower / 5 Lenses / 10.4 Fluid Level Stripper Plate Analyzer 7.1 Air Lines 13 Photo Check 7.2 Compressor Control 13.1 Resolution 7.3 Relief Valve 13.2 Uniformity 7.4 Regulator / 1 General Inspection 7.5 Filter-Compressor 7.6 Drain Storage Tank Initial 25X "X" coordinate counter inoperative. A new counter is on order by the customer. Form No. MS-103 March 26, 1966 GROUP 1 SECRET -4- EXCLUDED FROM AUTOMATIC DOWNGRADING AND DECLASSIFICATION Approved For Release 2006/08/31 : CIA-RDP78 4 70A001100060006-9 Approved For Release 2006/08/31 : CIA-RDP78BO477OA001100060006-9 SECRET PREVENTIVE MAINTENANCE SCHEDULE CHECK LIST TWO-MONTH INTERVAL PRECISION ENLARGER, 10-20-40X PAR 249 30 Apr 69 _ I I 25X1 Assigned To: Date: 2 Apr 69 Machine Serial No. 113 (Army) / Item D. ri.tion / Item Description 1 Film Transport 8 Vacuum Pump Assembly 1.1 Static Removal Unit 8.1 Hoses and Couplings /? 1.2 Guide Roller Flanges 8.2 Pump / 1.3 Air Knives 8.3 Oil Level / 1.4 Belts and Pulleys 9 Lamp House Assembly 1.5 Lubricate Bearings / 9.1 Housing 2 Easel and Stencil Assembly / 9.2 Filter (Photographic) / 2.1 Easel / 9.3 Light Leaks / 2.2 Air Pressure System / 9.4 Lamp House Blower / 3.1 Glass / 10.1 Ejectors / 3.2 Lamps / 10.2 Hoses and Couplings 4 Negative Gate Interlock / 10.3 Blower / 5 Lenses / 10.4 Fluid Level Stripper Plate Air Pressure System 10 Immersion Sy:;tem 7.1 Air Lines 13 Photo Check 7.2 Compressor Control 13.1 Resolution 7.3 Relief Valve 13.2 Uniformity 7.4 Regulator 1 General Inspection 7.5 Filter-Compressor 7.6 Drain Storage Tank Initial 5X lOX condenser plano glass removed and replaced (Part No. 1160-250). Analyzer Form No. MS-103 March 26, 1966 GROUP I SECRET _ 5_ EXCLUDED FROM AUTOMATIC DOWNGRADING AND DECLASSIFICATION Approved For Release 2006/08/31 : CIA-RDP7 B04770A001100060006-9 Approved For Release 2006/08/31 : CIA-RDP78BO477OA001100060006-9 SECRET Nome PAR 249 30 Apr 69 PREVENTIVE MAINTENANCE SCHEDULE CHECK LIST TWO-MONTH INTERVAL PRECISION ENLARGER, 10-20-4OX Assigned To: I 25X1 Date: 1 Apr 69 / Item D. , it.tion / Item Description 1 Film Transport 8 Vacuum Pump Assembly / 1.1 Static Removal Unit 8.1 Hoses and Couplings / 1.2 Guide Roller Flanges 8.2 Pump / 1.3 Air Knives 8.3 Oil Level / 1.4 Belts and Pulleys 9 Lamp House Assembly 1.5 Lubricate Bearings 9.1 Housing 2 Easel and Stencil Assembly V 9.2 Filter (Photographic) / 2.1 Easel / 9.3 Light Leaks / 2.2 Air Pressure System 9.4 Lamp House Blower / 10 Immersion System 3.1 Glass 10.1 Ejectors 3.2 Lamps 10.2 Hoses and Couplings / 4 Negative Gate Interlock 10.3 Blower / 5 Lenses / 10.4 Fluid Level Stripper Plate System / 11 Lamp House Control Analyzer 7.1 Air Lines 13 Photo Check 7.2 Compressor Control 13.1 Resolution 7.3 Relief Valve 13.2 Uniformity 7.4 Regulator / 1 General Inspection 7.5 Filter-Compressor 7.6 Drain Storage Tank Initials 25 F REMARKS: "Y" coordinate counter repaired and readjusted. Form No. MS-103 March 26, 1966 GROUP 1 SECRET -6- EXCLUDED FROM AUTOMATIC DOWNGRADING AND DECLASSIFICATION Approved For Release 2006/08/31 : CIA-RDP78BO477OA001100060006-9 Approved For Release 2006/08/5Ecl P78B04770A001100060006-9 PAR 249 30 Apr 69 PREVENTIVE MAINTENANCE SCHEDULE 'CHECK LIST TWO-MONTH INTERVAL PRECISION ENLARGER, 10-20-10X Assigned To: n Date: 2 Apr 69 / Item D .~cription / Item Description 1 Film Transport 8 Vacuum Pump Assembly 1.1 Static Removal Unit 8.1 Hoses and Couplings / 1.2 Guide Roller Flanges 8.2 Pump / 1.3 Air Knives 8.3 Oil Level / 1.4 Belts and Pulleys 9 Lamp House Assembly / 1.5 Lubricate Bearings / 9.1 Housing g 2 Easel and Stencil Assembly / 9.2 Filter (Photographic) 2.1 Easel / 9.3 Light Leaks / 2.2 Air Pressure System 9.4 Lamp House Blower 10 Immersion Sy :item / 3.1 Glass / 10.1 Ejectors 3.2 Lamps 10.2 Hoses and Couplings 4 Negative Gate Interlock 10.3 Blower 5 Lenses 10.4 Fluid Level / 7 Stripper Plate Air Pressure System 7.1 Air Lines 13 Photo Check 7.2 Compressor Control 13.1 Resolution 7.3 Relief Valve 13.2 Uniformity 7.4 Regulator 1 General Inspection 7.5 Filter-Compressor 7.6 Drain Storage Tank Initials J X SECRET Form No. MS-103 March 26, 1966 GROUP 1 EXCLUDED FROM AUTOMATIC DOWNGRADING AND DECLASSIFICATION Analyzer Approved For Release 2006/08/31 : CIA-R?P78BO477OA001100060006-9