REPORT OF TRIP TO(Sanitized)

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A002000060001-4
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
1
Document Creation Date: 
December 28, 2016
Document Release Date: 
December 4, 2002
Sequence Number: 
1
Case Number: 
Publication Date: 
October 10, 1967
Content Type: 
MFR
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A002000060001-4.pdf62.77 KB
Body: 
Approved For Release 2003/01! 1 P78B047A002000060001-4 Declass Review by NPIC/TDS/D-1061-67 NIMA/DOD 10 October 1967 25X1 25X1 25X1 25X1 25X1 25X1 25X1 25X1 25X1 SUBJECT: Report of Trip to 25X1 1. On 4 October 1967, I made a tri to to discuss 25X1 the 15? eyepieces for the Zoom 70 with I land to discuss the problems found 25X1 in the 13X magnifiers with 0 I a so returned the fine focus microscope mount to =and left a 13X magnifier with 1I for modification. 25X1 2. representative, and myself inspected and discussed the 15 eyepieces for the Zoom 70. The tilted eye- pieces have an unacceptable feature in that they rotate the images slightly away from the operator as the inter-pupilary distance is enlarged. Ipre- 25X1 sented alternate approaches to solving this; the most realistic being t e addition of a capability to adjust the prisms to compensate for the rotation. I Istated, however, that to build the new eyepieces would require a new con- ract since they feel that the present eyepieces meet the requirement of the existing contract. The production costs of the proposed version of the eye- pieces will be about 20% higher than the estimate given for the present 15? eyepieces. I agreed to send a Zoom 70 which had been fitted for a wide span rhomboid and ould t en mount the 15? eyepieces on it and send it back for operational evaluation. The wide span rhomboid has image rotation elements in it which will compensate for the rotation in the eyepieces. There- fore, the eyepieces can be evaluated in this mode operationally. 3. met me at his facility and I ex- plained to him the problems encountered in using the 13X magnifiers. The first problem being that the sharp edges on the retie e retaining ring cause scratches in the film. I I would polish off these edges at no cost to the Government- e secon pro em is parall caused h the separation between the reticle and the film.id that would investigate several approaches to solving this pro lem and sub- mit estimates for performing the desired work. I left a 13X magnifier kit with and he said they would modify it to reduce or eliminate the para x anen return it for Government approval. No cost to the Govern- ment would be involved in modifying the magnifier I left. 25X1 25X1 25X1 25X1 Distribution: Orig - Rt & File 2 - NPIC/TD/DS/ESB Exploitation Systems Branch, DS/TDS Approved For Release 2003/01/28 : RDP78B04770A002000060001- ;;d r '" " ?roi s lards:! LJ' ` do riJ n and ~'C?Jl:zssi;icatian