ROLLER TRANSPORT REVERSAL PROCESSOR (12-INCH)

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A002400050063-3
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
3
Document Creation Date: 
December 28, 2016
Document Release Date: 
May 9, 2005
Sequence Number: 
63
Case Number: 
Publication Date: 
February 26, 1965
Content Type: 
PERRPT
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A002400050063-3.pdf146.56 KB
Body: 
L L Approved or Release 2005/0610&: ciA-1DP78B0477OA002400050063-3 QUARTERLY REPORT PAR 214 26 Feb 65 SUBJECT: Roller Transport Reversal Processor (12-Inch) TASK/PROBLEM 1. Design and fabricate a versatile self-threading photographic processor capable of processing both cut sheet and continuous webs of photo- graphic material and adaptable to a process yielding either standard nega- tive or reversal images. Interchange between processes to be accomplished with a minimum amount of effort. DISCUSSION 2. During the report period, all items required to build the processor were released for fabrication. 3. On 17 December 1964, a trip was made to the customer's facility to ascertain room location and size for the equipment and to discuss problems related thereto. At this time, a further requirement for the machine was indicated. The dry end of the machine is required to be in a dry, lighted area. 61166111-- SECRET Excluded from automatic dowagradlag ad -34- declassilicatloa 4. Installation drawings were prepared and submitted to the customer. These drawings show the location of the machines in the room, the location of service lines and the means of locating the dry end of the machine in a lighted dry area. 5. Heat load and air discharge data were transmitted to the customer in the Monthly Report, Contrac~ dated 22 January 1965. 6. The fabrication schedule appears to have slipped about two weeks, however, we are not prepared to predict at this time whether the previously anticipated delivery date (30 JiLy 1965) will be affected. 7. Sketches of proposed briefing aids were submitted for customer approval. PLANNED ACTIVITY 8. Complete fabrication, mechanical and chemical checkout subsequent to delivery. 25X1 Declass Review by NGA. Approved For Release 2005/06/06 : CIA-RDP78BO477OA002400050063-3 Preliminary Approved For Re FAM' MO NG~ 8BO4770AO#"00050063-3VJ As of 11/18/64 //AAe6V I . INSTRUMENT A. Name Photographic Processor RT-12-R B. Manufacturer C. Contract Number II. PHYSICAL FEATURES A. Number of Component Parts 20 B. Dimensions of the Largest Component Part: Length 3 Ft. 0 In. Height 5 Ft. 0 In. Width 2 Ft. 6 In. C. Weight of Largest Component Part 700# (Crated) D. Total Weight of Instrument 7000# Installed - Empty E. Overall Dimensions Assembled: Length 15 Ft. 9 In. Height 5 Ft. 6 In. Width 5 Ft. 0 In. F. Type of Base of Mount: Flat X Three Point Suspension Four Point Suspension G. Does Instrument have built-in mobility? No H. Is the instrument particularly sensitive to vibration? No I. Are any special or unusual tools or fixtures necessary or adviseable for the installation or maintenance of this equipment? No III. UTILITIES A. Electrical: ts AC DC Voltage , 208 Vol Volts Current Frequency Nr. of phases Nr. of wires Power required by equipment 200 Watts` Watts Type of outlet required: Tw , Three Prong Twist Lock , Permanent Installation X Should the equipment be shie]ded, either from external electro- magnetic signals, or to prevent interference with other equipment? No: Machine radiation does not carry secure information; Machine is not sensitive to radiation. Approved For Release 2005/06/06 : CIA-RDP78BO477OA002400050063-3 Approved For i Room tern Output If air Page 2 Photographic Processor RT-12-R e 2O6 : CIA-RDP78BO477OA002 00050063-3 70 OF ~Xoning: erature f Instrument ust be filtered, what Humidity 50% RH BTIJ/Hr. . maximum permissible particle size ne? Not required / What particle count? in micr particle Direct con per cubic foot. he desired air temperature to instrument? Should discharged air be ducted separately? Yes (From Dryer Is discharged air noxious? No toxic? No Connector siz is moment 6" C. Plumbing Is wat.,f required for the i Astri.ument? Yes X No _ Water } es:;;,' 30 F3IG Flow in GPM 10 Typo of water desired: ,7:-ay-t, 130 of 10 ?F Taghilled 50 OF 50F Flit ere '-3()-O-_& 5()()F o-ztn,t vu1 rne. 10 t, Type or' iJ- _ required: 10 ?F Particle size and count per Galvanized Copper X (Water) t,a.it_Ie s >t E. I or Plastic For chemicals Is fluor drai.? 1 -quirked`? Yes X No j )'_ca t d in Galvanized drain 14b Silicon Iron Pia.>tic drain Glass drain i" D. Corn tied Air. D. mc_t rot cc? ,oct ,x'=> 1y2" IN, i'ype of ~or'n Screwed F, 2 ax W or fre( ? Yes CF ,; Yes Instrument Air) E. Va-Gm' Vacuum req' l r "r1 e f' Hq Disp;_a e_met'. C FM in the ,.:vent a.idit octal space is required for env_rorLiY*n:tal conditions or !iti1.-7t ier mont mcn(-cd above, use the; reverse side of this form. Approved For Release 2005/06/06 : CIA-RDP78BO477OA002400050063-3 -