DIGITAL READOUT COUNTERS

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A002900020056-9
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
3
Document Creation Date: 
December 28, 2016
Document Release Date: 
August 30, 2005
Sequence Number: 
56
Case Number: 
Publication Date: 
August 10, 1964
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A002900020056-9.pdf145.03 KB
Body: 
STAT Approved For Release 2005/11/21: CIA-RDP78B04770A002900020056-9 DIGITAL READOUT COUNTERS is STAT STAT STAT The Digital Readout Counters manufactured b are used to count pulses from a measuring engine reading ead. Two things are done with the count: A. The count is converted to a decimal digit reading and displayed to the operator on Nixie tube counters. B. The count is stored in a synchronizer buffer and transmitted to a computer, via dataphone, as binary pulses in a standardized coded sequence. The counter usually consists of four chassis: A. A control panel B. A Synchronizer C. An x-axis counter D. A y-axis counter Additional counter chassis may be added to add axes, and a 4-axis counter will have two additional chassis. There are currently on order three 2-axis systems and one 4-axis system and spares. The 2-axis counters are in work and delivery of the first one will be on or about August 22 as indicated in my pre- vious report. All the circuit boards are complete for all three systems. Wiring of counters and control panel is complete for the first unit and checkout will start today. Wiring of the first synchronizer started today and will take about a week. The circuit boards on the spares con- tract will be delivered concurrently with the first 2- axis system. The information which required by August 1 was received verball and aid not old up the 2-axis systems. indicated the 2-axis s stems would be used with the eading heads so ill include the lamp excitation power and the $ Vol power from connectors on the synchronizer. The 4-axis counter Declass Review by NGA. Approved For Release 2005/11/21: CIA-RDP78B04770A002900020056-9 Approved For .ease 2005/11/21: CIA-RDP78B0477*2900020056-9 STAT STAT STAT STAT STAT STAT Digital Readout Counters August 10, 1964 will be used with thel reading head and that is a different story. The pulse data which received from id not correspond to the data which received from who is Chief Engineer at Further, that the pulse measurem maae on a lunit in-house '~;R ne nas are different from anything quoted. suspects that the head does not Include the pulse shaping circuitry to make it operate like a Class C amplifier with a constant pulse output. It appears that the head output pulse may be varying with head pickup conditions like a Class A amplifier. 'STA~ feels that making a counter, which counts pulses rom a signal generator, count pulses from a transducer should be very simple and straightforward. He would expect the problems to arise when the counter is hooked to the computer. Generally, transmitting to and receiving from a computer is a much more difficult interface. STAT STAT STAT STAT STAT STAT STAT will get clarification of the pulse shape rom The pulse shape information in order to make an October 1 delivery. will be nee e y no ater than September 15, 1964, The cable lengths for the 4-axis system are to be specified by The cable length information is needed by y e -em er 1 1964, in order to fit into their manu acturing schedule. advised 0 to make the cables 15 ft long g ina in ormation was not available in time. Since all the counters were contracted for at about the same time, the price was reduced about 5% from the original quote. Except for the problems generated by the pulse, 0 has been well satisfied wi by the customer. He says that it is unusual that they are brought in on a job early enough to have adequate delivery time. I would consider that a compliment to I rs foresight. STAT STAT that and possibly as soon as they have checked out the unit in-house, preferably sometime around August 22. It is important that they discuss the pulse Approved For Release 2005/11/21: CIA-RDP78BO477OA002900020056-9 Approved For?ease 2005/11/21 : CIA-RDP78BO477902900020056-9 STAT Digital Readout Counters matching interface solution with August 10, 1964 indicated that was intelligent STAT 0 0 and knowledgeable. He unders oo the circuitry and asked intelligent questions. A second visit would probably be valuable after has worked on the actual unit. Approved For Release 2005/11/21: CIA-RDP78BO477OA002900020056-9