NOTICE: In the event of a lapse in funding of the Federal government after 14 March 2025, CIA will be unable to process any public request submissions until the government re-opens.

T&E REPORT NO. 70-10 ON THE(Sanitized)2X OBJECTIVE FOR THE ZOOM 240R STEREOSCOPE SYSTEM IN MONOSCOPIC MODE

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B05171A000600010017-5
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
2
Document Creation Date: 
December 28, 2016
Document Release Date: 
March 30, 2004
Sequence Number: 
17
Case Number: 
Publication Date: 
October 6, 1970
Content Type: 
MF
File: 
AttachmentSize
PDF icon CIA-RDP78B05171A000600010017-5.pdf110.67 KB
Body: 
Approved-For Release 2004/05/05: CIA-RDP78BM71A000600010017-5 NPIC/TSG/RED/SDB-01+7_70 6 October 1970 RANDUM FOR: Chief, Engineering Support Division, TSG ATTENTION THROUGH SUBJECT Chief, Technical Evaluation Branch, ESD/TSG Chief, Research & Engineering Division, TSG ME Report No. 70-10 on the 0 2X Objective for the Zoom 24OR Stereoscope System in Monoscopic Mode 1. This is a good, objective report. The format of detailed re- quirements, results, and procedure makes for ease of reading and under- standing. The progression from Introduction, Sugary of Results, etc., good. 2. Some specific comments follows a. The hbstract states "...that the device is suitable for procurement subject to modification." Paragraph 3.1 concludes that "The device is considered to be acceptable to NPIC for procurement in its present condition and configuration." Perhaps rephrasing would remove this apparent contradiction. b. Paragraph 3.2 (b). lenses are coated, c. Paragraph 2.1.2 reports that "The 2X Objective is not parfocal..." The 240 system is far from parfocal within itself. 1X mono vs. 2X stereo is parfocal, IX mono vs. 0.5X mono is not par- focal by 3 3/8 inches. Probably the important point of this state- ment is that the 2X Objective lens is parfocal with the 2X stereo mode. Also, can you realistically visibly determine the point of best focus to 0.001 inch? As a guess, depth of focus for the system is perhaps at least three times this much. d. Paragraph 5.1.1 (e). The meaning is not clear. separation is determined by rotating the arms. The statement says that the arms are restricted in rotation, yet minimum and maximum separation does not change. Declass Review by NIMA/DOD Approved For Release 2004/05/05 : CIA DR A000600010017-5 _. F*elnAnf fr,., ,.4..,,,4. 25X1 25X1 SECRET ApprovedSor Release 2004/05/05: CIA-RDP78B171A000600010017-5 SUBJECT: T& Report No. 70-10 on the F -12X Objective for the Zoom 240R Stereoscope System in Monoscopic Mode. e. paragraph 5.1.2 states that "It is desirable that the 2X Objective be parfocal with the Zoom 24+OR Stereoscope System." This is not possible since the 2 system is not parfocal within itself. Again, the important point probably is that 2X Objective and 2X stereo is parfocal. Indeed, any reporting of parfocality is a reporting of the pod/lens system and. not a reporting of the 2X Objective itself.. f. Paragraphs 5.2.2 and 5.3.2 (d) These paragraphs raise the question as to whether the system would remain in focus when using a cover glass. g. Paragraph 5.3.2 (e) reports a resolving power of eight lines/mm/power, whereas Paragraph 5.2.5 reports approximately five lines/mm/power. SDB/ /TSG PIC Distribution: Original - Addressee I - SDB/RED/TSG/NPIC 1 - Pro ect Monitor NPIC /TSG/RID/SDB Approved For Release 2004/05/05 : CIA-RDP78B05171A000600010017-5 SECRET 5X1