NEWLY IDENTIFIED THERMAL POWERPLANTS IN PEKING MILITARY REGION, CHINA

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78T05162A000200010090-0
Release Decision: 
RIPPUB
Original Classification: 
T
Document Page Count: 
5
Document Creation Date: 
December 28, 2016
Document Release Date: 
August 24, 2011
Sequence Number: 
90
Case Number: 
Publication Date: 
September 1, 1972
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP78T05162A000200010090-0.pdf186.85 KB
Body: 
Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 PNOT06RAPNIC INTERPRETATION REPORT NATIONAL PHOTOGRAPHIC INTERPRETATION CENTER NEWLY IDENTIFIED THERMAL POWERPLANTS IN PEI(ING MILITARY REGION, CHINA 25X1 T SEPTEMBER 1972 COPY NO. ~ 21. 2 PAGES PIR-047/72 Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 TOP SECRET RUFF NEWLY IDENTIFIED THERMAL POWERPLANTS IN PEKING MILITARY REGION, CHINA ABSTRACT 1. This report is a summary of 42 thermal powerplants newly identified in Peking Military Region (Inner Mongolia, Shansi, and Hopeh Provinces) on photography of January, February, and July 1972. The report contains text, a table, a map, and a photograph. INTRODUCTION 2. With the addition of these 42 newly identified thermal powerplants (Figure 1), the number in Peking Military Region increased to 59. Three of the newly observed plants were under construction. Approximately 80 percent of the military region was observed on cloud-free photography. BASIC DESCRIPTION 3. The 42 newly identified thermal powerplants use coal as the principal fuel. Like most of the previously identified thermal powerplants they have integral boiler houses and generator halls (Figure 2), The new powerplants range in size from small to medium and in many cases, they are either next to a rail line or near a water source, 4. Table '1 (keyed to Figure 1) summarizes the 42 plants and includes the name, BE number, coordinates, status, and physical features of each plant. .1.10 ? 00.' INNER N10NGOLIA ~~ ,.120? 00( ~ NEWLY IDENTIFIED THERMAL POWERPLANT FIGURE 1. NEWLY IDENTIFIED THERMAL POWERPLANTS IN PEKING MILITARY REGION, CHINA 100 J Table i. Thermal Po werpfants in Peking Military Region, China Item Numbers keyed to Figure 1 J Item Geographic Type of No of No of No of Presence of No o1 Support No Installation Coordinates Status Fue] Stacks Cooling Ponds Coaling Towers Switching Yards/ Substations B uildings 1 To~sen-ho-la~ka 45-05-30N Operational Coal 1 1 D Yes p Thermal Powerplant 116-50-DOE 2 Su~nl-te~yu-clti 42-03-0ON Operational Coal 1 7 0 Yes 3 Thermal Powerplant 112-5750E 3 Pao~chang 41-53-0ON Operational Coal 1 3 Thermal Powerplam 11517-20E 0 No 11 4 Wuchuan 41-05-7 DN Operational Coal 1 1 D No 1 Thermal Powerplant 111-274DE 5 So-la4e 4109-05N Operational Coal 2 D 1 No 2 Thermal Powerplant 112-19-0OE 6 Chi-nm9 41-0240N Operational Caal 1 2 0 No g Thermal Powerplant 113~06~50E 7 Lm-ho 40-04-40N Operational Coal 1 4 0 Yes 5 Thermal Powerplam iD7-24-30E B Yimshan 3937-20N Operational Coal 7 1 0 No 5 Thermal Powerplant 10653-0OE 9 Tung-sheng 39-083DN Operational Coal 1 2 0 No g Thermal Powerplant 10&59-50E 10 Chun-koxrh~chi 39-00-10N Operational Coal 1 1 Thermal Powerplam 11D~57-10E 0 No 15 11 Chia~chia-wan 39-5530N Operational Coal 1 1 D No 2 Thermal Powerplant 71137~OOE 12 Tiemchen 40-27-05N Operational Coal 1 2 0 Yes 7 Thermal Powerplam 174-04-15E 13 Piemkuan 3&26-30N Operatiowl Coal 1 2 0 Yes 3 Thermal Powerplam 17128-50E 79 Ho~cho 39Q2-25N Operational Coal 1 2 2 Yes 6 7hennal Powerplam 7110745E 15 Shouduien 39-79-0ON Operational Coal 1 4 Thermal Powerplant 112~26~5DE 2 No {g 1G Chmg-tzu~yao 39-3S-0ON Under Coal 1 0 1 Yes 3 Thermal Powerplant 113-03-0OE Construction 77 Huu~yuao 39-02-10N Operational Coal 3 p p yes 6 Thermal Powerplant 113-02-0OE 18 Hsing-hs~en 38-28-0ON Operational Coal 1 0 Yes 0 Thermal Powerplant 111-07-30E 19 Li-shah 37-31-05N Operational Coal 1 2 D Yes p 7hennal Powerplant 71108-55P. ZO Lm-Im 3745-0DN Under Coal 1 2 0 Yes p Thermal Powerplant i7D~54-10E Construction 21 Chung~yan9 37~20~50N Operational Coal 1 2 D Yes p Thermal Powerplam 111-1030E 22 Hsieh~chia-ping 3GAD30N Operutrooal Coal 1 0 4 Yes p 7hennal Powerplant 71177-05E 23 Yu~she 37-04-30N Operatmnal Coal 1 1 0 No 2 Thermal Powerplam 112~57~50E 24 Hsao-chungasun 36-33-OON Operational Coal 1 2 0 No g Thermal Powerplant 17218-0DE 25 Hvao-thong-tsun 363240N Operational Caul 1 7 p yeS 0 7hennal Powerp{am 11219-0OE 26 Hseng-mn9 35-59-0ON Operational Coal 1 1 D No 3 Thermal Powerplam 110-52 ~5E 27 Lin-ten 36-04-52N Operunonal Coal 1 3 0 Yes 5 Thenttal Powerplant 177-3138E 28 Homma 36-37-OON Opeial tonal Coal 1 0 16 Yes g Thee mat Powerplant 1174730E 29 Wen-hsi 3541~10N Opaotuonal Coal 1 2 0 Yes p Thee mat Powerplam 111-1230E 30 Yun~chen9 3502-7 DN Operational Coal 1 2 0 No p Thermal Power plan) 110$93DE 31 Luon-pm9 405&25N Dperatonal Coal 1 1 9 Yes p Thermo] Powerplant 1=igu re 21 117-05-35E - 32 Hsuarohoz 40-3530N Operanonal Coal 2 1 0 No p 7hennal Powerplant 71504-50E 33 Tung~chun-Chuang 40-2140N Operational Coal 1 1 0 Yes 8 7hennal Powerplant 11639-05E 34 Nm~lan-shah 40-12-0ON Operational Coal 1 1 0 Yes p Thermal Powerplant 11639-OOE 35 Ymchan9 39-5240N Operational Coal 1 7 0 Yes 6 Thee mat Powerplam 174-26~ODE 3fi Tsany-hsien 3B-19~50N Operational Coal 1 1 0 Yes p Thermal Powerplam 116-5020E 37 Po-i ou 38-03-50N Operatronal Coal 2 2 D No q Thermal Powerplant 116-3440E 38 Sung-yuan 37-36-20N Operational Coal 1 1 D Yes 3 Thermal Powerplant 7164230N 39 Heny-shw 37A4-30N Operational Coal 1 2 0 Yes 3 Thermal Powerplant 115-00-50E 40 Te-thou 37-27~59N Opelanonal Coal 1 1 4 Yes ip Thermal Power Plant 11G1534E 47 Hsmyaai 37-05~75N Oparauonel Coal 1 0 4 Yes 2 Thermal Powerplam 114-29ADE 42 Shu-lu 36-54~10N Operational Coal 1 2 0 Yes 7 Thermal Powarplanl 115-7215E -1- 1 l TOP SECRET RUFF ~_ Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 25X1 z~xi Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 25X1 TOP SECRET RUFF MAPS OR CHARTS ACIC. Series JNC, Sheet JN 25, scale 1:2,000,000 REQUIREMENT NPIC/IEG/EGD/NECB Project 120201OK TOP SECRET RUFF Sanitized Co A roved for i ~ r ?24 CIA-RDP78T05162A000200010090-0 l py pp Release 2011/08/ Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0 TOP SECRET TOP SECRET Sanitized Copy Approved for Release 2011/08/24 :CIA-RDP78T05162A000200010090-0