OPTICAL EQUIPMENT LIST
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP79B00873A000800010030-3
Release Decision:
RIFPUB
Original Classification:
K
Document Page Count:
6
Document Creation Date:
December 28, 2016
Document Release Date:
October 18, 2012
Sequence Number:
30
Case Number:
Content Type:
MISC
File:
Attachment | Size |
---|---|
![]() | 250.85 KB |
Body:
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
O~'TICAL I!;QUI.1?MENT LIST
Iescription.
Precision
#1 Diopter telescope This is one of the most important pieces 1/4 diopter
of equipment in the kit. In order to
accurately magnify microscope imagery
for measurements of resolution, depth of
focus, parfocalization, etc. , a telescope
of the highest quality is required. IL must
not introduce any additional aberrations
into the system. Its uses are too numerous
to give in this proposal, However, amore
complete description of its applications wild
be furnished in the operator's manual sup-
plied vaith the kit. The telescope selected
? has the decided advantage of "standardizing"
the operator's eye. ~It eliminates confusing
eye accommodation from the operator's eye
and is adjustable to standardize the acuity of
different individuals. An eyepiece reference
scale allows a convenient method of returning
to a particular individual's eye. It also in-
cludes afocusing adjustment calibrated from
-6 to +3 diopters in 1/4 diopter increments
fox measuring accommodation ranges in
adjustable binocular eyepieces. The 3X mag-
. nification allows the operator to check resolu-~
tions of irnstruments exceeding the resolution
capability of the eye. It is felt that~no com-
promise of either quality or versatility can be
tolerated in fulfilling these specific requirements of
the kit. This instrument will certainly n.ot be a
compromise in either respect.
#2 10X eyepiece A lOX wide field eyepiece,which will accommodate
the 21mm reticles supplied i.n this kit will be in-
clt~ded. It will be calibrated under the contractor's
supervision. However, calibration of this eye- _.
piece is not considered necessary for the per-
- forman.ce of any of the tests herein described.
This calibration can. optionally be deleted by the
sponsor .. with an appropriate reduction i.n the
cost of the lit. It should be noted that the only
. calibrations necessary must be performed on the
. equipment to be tested with the aid of a stage
micrometer. 12
-?- Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
? Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
- TABLI; II. (cont`d.) -
Descri,.ptio~ Precision
#3 Astigmatism azid This item will be custom manufactured. Orthogonality
orthogonality target No standard targets for astigmatism could to better than
i be found.. The target consists of 29 cross 0.~5 minute of
~ lines located on the X and Y axes of the arc.
' target plate as well as on the diagonals.
For astigmatism the plate is designed to Length to
accommodate fields of view from 2mm f 0. 0002
to approximately 100mm. The cross inch.
lines will be approximately 5 microns
` wide..
For economy, both the targets for astig-
matism and orthogonality were put on the
same plate.
For orthogonality and linear dimensional
check of mechanical stages, the positions
of each cross line center will be accurate
tot 5 microns. On X and Y tran.;lations
of 3.5 inches each, the accuracies at the
right are applicable.
The target will be a vacuum deposition of
chrome on glass. This type of target is
easy to view ~=rith transillumination and was
chosen over other target materials because
of its durability.
#4 21mm reticle 0.5mm-squares making a grid over entire 0. 5mm
' field of view for distortion tests
#5 21mm reticle Cross line scales lOmm long horizontally O, lmm
and vertically, each divided into 100 parts..
#6 21mm reticle 24 concentric circles, 0. 5mm to 12mm
diameter in 0. 5mm increments
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
ABLE II (cont'd.)
Item
#7 Resolution target
r
#8 Stage micrometer
#9 Microscope grid
#10 Microscope grid
#11 Large field grids
#12 Translucent Scale
Description Precision
The resolution target ~,-i11 consist of three Ilicluded in
groups. Each group will contain 11
patterns covering ra.z~ges from 1 to 10
1/mm, 10 to 100 1/inm and 100 to 1000
1/mm respectively. Each single fre-
quency pattern will contain 15 clear bars
on an opaque background. Maximum
variation in width betvti,~een the light and
dark bars will be less than 5% over the
range from 1 to 300 1/mm. Density
difference will be greater than 2.0. The
target will be mounted on a 2 inc12 square
glass plate.
description
ror use i.n calibrating reticles and measuring O. Olm~n
magnification, 2mm scale divided into 200
0. Olmm increments mounted on a 25mm x. 75mm
glass slide.
50mm x 50mm, 2mm squares. ~4.ccuracy f 1.Omm
0. Olmm overall, line widths. 0. 07.rnm and
0. 15mm.
21mm disc, 0. lmm squares 0. 1mm
Several large grids of different dimensions 1.Omm
will b~ provided. 9" x 9", 411 x 5" can be
provided at relatively small cost for exami-
ning distortions. The size of the squares
will be lmin x 1mm or 0. 2" x 0. 2", depend-
ing on the overall size of the grid. The grids
will be on a dimensionally stable Cronar base.
Line widths will be .003" and .006". Spacing
will be accurate to .0005".
Made from Cronar base grid
2mm increments, lOcm long with
numbers at each cm. -
,_ Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
-TAELE II (cony d.) - _ _
Precision
0. 001"
#14 Light meter
Descr. iption
A dial indicator with .001" divisions acid
1" measuring range will be provided with
a granite--base stand. The indicator can
be moved by means of an adjustable arm
to contact moving parts of instruments to
be measured. Accurate tot .0005" over
entire range.
The light meter will be a sizr~pl_e CdS ex-
posure meter with an appropriate con-
version chart for reading the light level of
a light tabie.
The accuracy
and precision of
this instrument
will be calculated
by the contractor.
Although not a
laboratory pre-
cision instru-
ment, it is felt
that its precision
is adequate for
field testing. .
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
?. Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
~ TAI3LE III -
MIiJCF3~,NICAL EQUIk~MENT LIST
Item Description
#15 Machinist scale 6" steel rule with four scales on the four 0. 5mm, 0. O1",
edges. 1/96", 1/64"
#1G Tape measure 6' retractible, .metallic tape measure 1/8"
#17 Calipers
English and metric scale vernier calipers 1/128" or
with inside, outside and depth capabilities 0. lmm
to approximately 5".
#18 Surface ~ 0 ? F to 300 ? F, magnetic clamp or
thermometer silicone grease .
#19 Tension tester A 5 lb. capacity spring scale for use with 1 oz.
film or film leaders with holes punched in
them. The leaders. or film to be supplied
by the customer.
#20 Foeppl vibration This target consists of two rows of .001" 0.001"
target diameter dots on a glass slide. The two
rows diverge;the first two dots are .001"
apart and the separation increases in
.001" increments to . 02".
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3
TABLE IV
MISCELLANEOUS EQUIPMENT LIST
Item
#21 Illuminator
#22 Variable angle
reflector
#23 N. D. filters
#24 Step wedge
#25 Spectral filters
#26 Polarizing filter
27 Lens brush
28 Hand magnifier
29 Stop watch
~k30 Flashlight
X31 Hole punch
Description
Variable intensity, variable position,
variable focus light source.
1-1/2" diameter front surface mirror in
adjustable position holder.
2" x 2" N. D. filters, 1.0, 1. 5 and 2.0 N. D. ;
carbon suspension in gelatin
1" x 5-1/2" photographic silver 21-step
tablet
Three Wratten color separation filters,
3" x 3"
One 5" x 5" polarization filter, 0.01" thick
1" width all camel hair lens and negative
brush
3" diameter, 8" focal length, handle
30-minute elapsed time capacity; individual
color coded stop, start, and reset buttons
A small flashlight with awell-directed beam
A single-hole paper punch to make the holes
necessary for the tension tester
Custom fitted ~~vith foam and straps where
necessary to protect contents. Small enough
to be carried on airplane trips.
Precision
N/A
N/A
N/A
1/10 sec
N/A~
N/A
N/A
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3