OPTICAL EQUIPMENT LIST

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP79B00873A000800010030-3
Release Decision: 
RIFPUB
Original Classification: 
K
Document Page Count: 
6
Document Creation Date: 
December 28, 2016
Document Release Date: 
October 18, 2012
Sequence Number: 
30
Case Number: 
Content Type: 
MISC
File: 
AttachmentSize
PDF icon CIA-RDP79B00873A000800010030-3.pdf250.85 KB
Body: 
Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 O~'TICAL I!;QUI.1?MENT LIST Iescription. Precision #1 Diopter telescope This is one of the most important pieces 1/4 diopter of equipment in the kit. In order to accurately magnify microscope imagery for measurements of resolution, depth of focus, parfocalization, etc. , a telescope of the highest quality is required. IL must not introduce any additional aberrations into the system. Its uses are too numerous to give in this proposal, However, amore complete description of its applications wild be furnished in the operator's manual sup- plied vaith the kit. The telescope selected ? has the decided advantage of "standardizing" the operator's eye. ~It eliminates confusing eye accommodation from the operator's eye and is adjustable to standardize the acuity of different individuals. An eyepiece reference scale allows a convenient method of returning to a particular individual's eye. It also in- cludes afocusing adjustment calibrated from -6 to +3 diopters in 1/4 diopter increments fox measuring accommodation ranges in adjustable binocular eyepieces. The 3X mag- . nification allows the operator to check resolu-~ tions of irnstruments exceeding the resolution capability of the eye. It is felt that~no com- promise of either quality or versatility can be tolerated in fulfilling these specific requirements of the kit. This instrument will certainly n.ot be a compromise in either respect. #2 10X eyepiece A lOX wide field eyepiece,which will accommodate the 21mm reticles supplied i.n this kit will be in- clt~ded. It will be calibrated under the contractor's supervision. However, calibration of this eye- _. piece is not considered necessary for the per- - forman.ce of any of the tests herein described. This calibration can. optionally be deleted by the sponsor .. with an appropriate reduction i.n the cost of the lit. It should be noted that the only . calibrations necessary must be performed on the . equipment to be tested with the aid of a stage micrometer. 12 -?- Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 ? Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 - TABLI; II. (cont`d.) - Descri,.ptio~ Precision #3 Astigmatism azid This item will be custom manufactured. Orthogonality orthogonality target No standard targets for astigmatism could to better than i be found.. The target consists of 29 cross 0.~5 minute of ~ lines located on the X and Y axes of the arc. ' target plate as well as on the diagonals. For astigmatism the plate is designed to Length to accommodate fields of view from 2mm f 0. 0002 to approximately 100mm. The cross inch. lines will be approximately 5 microns ` wide.. For economy, both the targets for astig- matism and orthogonality were put on the same plate. For orthogonality and linear dimensional check of mechanical stages, the positions of each cross line center will be accurate tot 5 microns. On X and Y tran.;lations of 3.5 inches each, the accuracies at the right are applicable. The target will be a vacuum deposition of chrome on glass. This type of target is easy to view ~=rith transillumination and was chosen over other target materials because of its durability. #4 21mm reticle 0.5mm-squares making a grid over entire 0. 5mm ' field of view for distortion tests #5 21mm reticle Cross line scales lOmm long horizontally O, lmm and vertically, each divided into 100 parts.. #6 21mm reticle 24 concentric circles, 0. 5mm to 12mm diameter in 0. 5mm increments Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 ABLE II (cont'd.) Item #7 Resolution target r #8 Stage micrometer #9 Microscope grid #10 Microscope grid #11 Large field grids #12 Translucent Scale Description Precision The resolution target ~,-i11 consist of three Ilicluded in groups. Each group will contain 11 patterns covering ra.z~ges from 1 to 10 1/mm, 10 to 100 1/inm and 100 to 1000 1/mm respectively. Each single fre- quency pattern will contain 15 clear bars on an opaque background. Maximum variation in width betvti,~een the light and dark bars will be less than 5% over the range from 1 to 300 1/mm. Density difference will be greater than 2.0. The target will be mounted on a 2 inc12 square glass plate. description ror use i.n calibrating reticles and measuring O. Olm~n magnification, 2mm scale divided into 200 0. Olmm increments mounted on a 25mm x. 75mm glass slide. 50mm x 50mm, 2mm squares. ~4.ccuracy f 1.Omm 0. Olmm overall, line widths. 0. 07.rnm and 0. 15mm. 21mm disc, 0. lmm squares 0. 1mm Several large grids of different dimensions 1.Omm will b~ provided. 9" x 9", 411 x 5" can be provided at relatively small cost for exami- ning distortions. The size of the squares will be lmin x 1mm or 0. 2" x 0. 2", depend- ing on the overall size of the grid. The grids will be on a dimensionally stable Cronar base. Line widths will be .003" and .006". Spacing will be accurate to .0005". Made from Cronar base grid 2mm increments, lOcm long with numbers at each cm. - ,_ Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 -TAELE II (cony d.) - _ _ Precision 0. 001" #14 Light meter Descr. iption A dial indicator with .001" divisions acid 1" measuring range will be provided with a granite--base stand. The indicator can be moved by means of an adjustable arm to contact moving parts of instruments to be measured. Accurate tot .0005" over entire range. The light meter will be a sizr~pl_e CdS ex- posure meter with an appropriate con- version chart for reading the light level of a light tabie. The accuracy and precision of this instrument will be calculated by the contractor. Although not a laboratory pre- cision instru- ment, it is felt that its precision is adequate for field testing. . Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 ?. Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 ~ TAI3LE III - MIiJCF3~,NICAL EQUIk~MENT LIST Item Description #15 Machinist scale 6" steel rule with four scales on the four 0. 5mm, 0. O1", edges. 1/96", 1/64" #1G Tape measure 6' retractible, .metallic tape measure 1/8" #17 Calipers English and metric scale vernier calipers 1/128" or with inside, outside and depth capabilities 0. lmm to approximately 5". #18 Surface ~ 0 ? F to 300 ? F, magnetic clamp or thermometer silicone grease . #19 Tension tester A 5 lb. capacity spring scale for use with 1 oz. film or film leaders with holes punched in them. The leaders. or film to be supplied by the customer. #20 Foeppl vibration This target consists of two rows of .001" 0.001" target diameter dots on a glass slide. The two rows diverge;the first two dots are .001" apart and the separation increases in .001" increments to . 02". Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3 TABLE IV MISCELLANEOUS EQUIPMENT LIST Item #21 Illuminator #22 Variable angle reflector #23 N. D. filters #24 Step wedge #25 Spectral filters #26 Polarizing filter 27 Lens brush 28 Hand magnifier 29 Stop watch ~k30 Flashlight X31 Hole punch Description Variable intensity, variable position, variable focus light source. 1-1/2" diameter front surface mirror in adjustable position holder. 2" x 2" N. D. filters, 1.0, 1. 5 and 2.0 N. D. ; carbon suspension in gelatin 1" x 5-1/2" photographic silver 21-step tablet Three Wratten color separation filters, 3" x 3" One 5" x 5" polarization filter, 0.01" thick 1" width all camel hair lens and negative brush 3" diameter, 8" focal length, handle 30-minute elapsed time capacity; individual color coded stop, start, and reset buttons A small flashlight with awell-directed beam A single-hole paper punch to make the holes necessary for the tension tester Custom fitted ~~vith foam and straps where necessary to protect contents. Small enough to be carried on airplane trips. Precision N/A N/A N/A 1/10 sec N/A~ N/A N/A Declassified and Approved For Release 2012/10/18 :CIA-RDP79B00873A000800010030-3