REQUEST FOR APPROVAL OF A CONTRACT FOR A DIAGNOSTIC COMPUTER PROGRAM FOR THE HIGH PRECISION STEREO COMPARATOR (SANITIZED)
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP79B00873A001400010002-7
Release Decision:
RIPPUB
Original Classification:
S
Document Page Count:
6
Document Creation Date:
December 28, 2016
Document Release Date:
August 24, 2012
Sequence Number:
2
Case Number:
Publication Date:
June 8, 1970
Content Type:
MEMO
File:
Attachment | Size |
---|---|
CIA-RDP79B00873A001400010002-7.pdf | 292.77 KB |
Body:
pP
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
ExecutIve ne9,3:1,1
aumr,
0
NPIC/D-152-70
8 JUN 1970
MEMORANDUM FOR: Executive Director-Comptroller
THROUGH Chairman, Information Processing Board
SUBJECT
Request for Approval of a Contract for a ,
Diagnostic Computer Program for the High
Precision Stereo Comparator
1.? This memorandum requests approval for the commit-
ment of R&D funds for a NPIC contract. The specific request
is stated in Paragraph 8.
2, The High Precision Stereo Comparator (HPSC), which
is presently under development, is scheduled to become oper-
ational by the end of 1970. This sophisticated comparator
provides. stereoscopic measurements accurate to a fraction
of a micrometer (micron). This. extremely complex, computer
controlled, optical-electromechanical device is precision
engineered; however, as with every manmade device, trouble-.
shooting and maintenance will be required from time to time
to determine causes of failure as well as for keeping all
of the Components of the system in, good operating order and
in proper alignment. Regularly scheduled preventive mainte-
nance checks will have to be made in order to be assured
that the comparator and its numerous interrelated systems
and subsystems are functioning as required. This will ensure
that consistent and accurate data is provided. Since the
comparator system is so complicated and requires skills in
several specialized fields to diagnose subsystem failures, -
NPIC maintenance personnel have requested that the Research
& Engineering Division develop a Diagnostic Routine to help
cope with this problem. The proposed routine will be pro-
grammed into the HPSC's internal computer, a DDP-516, and
utilized to perform certain exercises to allow maintenance
personnel to quickly locate any problem areas and to help
isolate the specific subsystem or subsystems involved. This
program will provide a means to check out and verify the
forty subsystems of the HPSC in one-tenth the time required
czrn
I
efipi
Excluded frrm fRihnralic
dowrIzng r.aa
dee!2.35.lf!!icii
25X1
25X1
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
. _
SUBJECT: Request for Approval of a Contract for a Diagnostic
Computer Program for the High Precision Stereo
Comparator
for a manual check-out procedure (1/2 to 1 hour versus 10
hours). Utilizing this scientific approach, repairs and/or
alignments can be made with a minimum of down time for the
HPSC. Furthermore, variation of this routine can be used,,
at regularly scheduled intervals, to perform complete pre-
ventive maintenance checks. Additionally, the operator
can also check the relative stereoscopic orientation;
that is, the positions of the instrument's optical trans-
formation elements with regard to a set of test stereograms.
The routine is such that this can be done easily and quickly
at the beginning of each daily operation.
3. the prime contractor
for the. HPSC, has proposed a seven-to-ten month program
directed toward developing two series of diagnostic computer
routines designed to provide a rapid and controlled technique
for operating all computer directable.elements of the HPSC
on an individual basis. The routine will lead the mainten-
ance technician--through a question and answer technique--to
perform the necessary functions requiring his attention. The
diagnostic program will exercise all the mechanical moving
subassemblies throughout their ranges at a variety of speeds.
The technician will be able to observe the position of the
readout dials on the control console and visually inspect the
optical system through the eyepieces. He will also directly
observe the operation of the various electromechanical drives.
4. Some slight hardware modifications and the addition
of circuitry to gain access to otherwise unavailable elec-
tronic signals will be required. The contractor also pro-
poses to design, write, and prepare the two series of diagnos-
tic computer programs. He will deliver a punched paper tape
of the programs and add a manual switching panel to the com-
parator. Since this diagnostic routine is to be developed by
the NRI engineers having the most intimate knowledge of the
equipment, the undertaking is considered to have minimum
technical risk. The question is not of whether the routine
will work, but rather of how well and how simply it can be
made to function.
5. The Diagnostic Computer Program will provide an
error analysis capability for a unique High Precision Stereo
2
25X1
25X1
25X1
SMUT
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
? :.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
SUBJECT: Request for Approval of a Contract for a Diagnostic
Computer Program for the High Precision Stereo
Comparator
comparator built is the only contractor with 'an
_intimate enough knowledge of the equipment to develop the
routine; hence, this is a sole source item.
6. No follow-on or continuation of this program is
-H)anticipatd. The project has been coordinated with Technical
Services & Support Group/Engineering Support Division, Imagery
Exploitation Group/Photogrammetry Division, and Production
Support Group/Automated Information Division.
7. The security classification of this contract will
be CONFIDENTIAL. The association is CONFIDENTIAL, and the
.title is UNCLASSIFIED.
Attachments:
1. Proposal
2. Form 2420
? _ARTHUR C-.LUNDAHL
Director
National Photographic Interpretation Center
CONCUR
CONCUR:
-APPROVE
Intelligence
D te
25X1
2bAl
25X1
25X1
25X1?
3 ?
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
,t
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
SUBJECT: Request for Approval of a Contract for a Diagnostic
Computer Program for the High Precision Stereo
Comparator
Distribution:
Original - Exec. Dir.-Compt., return NPIC
1 - Exec. Dir.-Compt.
1 - Chairman, IPB
1 - DDI/IPC
2 - NPIC/ODir
1 - NPIC/TSSG
1 - NPIC/TSSG/RED
4
Ornp1,0
cV-Lbgli
? ?
25X1
25X1
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
UNCLASSIFIED. r-i CONFIDENTIAL f-1 ZECRET I I (specify)
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
? fthr?pi to PKUUURLMNI viviiiill rimen.Kviut
(.7 !rel than property or building maintenance Nlierepairs)
OFFICE/DIV/BR
REQUEST NO.
DATE OF REQUEST
I CERTIFY TH1
AMOUNT OF $,_
ESTIMATEE:25)(1
ARE
NPIC/TSSG/RED
5500-6111-70
25 May 70
AVAILADLE.CH:RGE TO FAN 0155-5340
---1.
PROJECT TITLE
Diagnostic
Computer Program
PR
25X1
NO AND DATE
riOPOSAL
25X1
13 March 1970
APPLICABLE ONLY TO REPAIRS AND MODIFICATIONS
TYPE OF SERVICE REQUESTED
TECHNICAL INSPECTION IS REQUIRED BY
_
RESEARCH/DEV
TRANSFER OF FUNDS TO
I IRECEIVING DEPOT T & I F5-1( TECHNICAL MONITOR,
GRANT(specify
OTHER GOVT. AGENCY
if applicable)
1 ITEMS To BE PICKED UP OR 1 I SERVICES PERFORMED AT:
I
REPAIR
MAINTENANCE
ITEMS TO BE REDELIVERED TO:
MODIFICATION
STERILITY CONTRACT CLASSIFICATION
WORK CLASSIFICATION
HARDWARE CLASSIFICATION
REPORTS CLASSIFICATION
CONFIDENTIAL
UNCLASSIFIED
UNCLASSIFIED
25X1
UNCLASSIFIED
SHORT SUBSTANTIVE TITLE AND/OR DESCRIPTION OF SERVICE TO BE PERFORMED
? Diagnostic Computer Program for the High Precision Stereo
Comparator (HPSC)
(See reverse for specific information
reouired on R&D requests.)
APPROVAL '
DESIGNATION CInNATIMP
DATE
SA/TSSG
25X1'
C 5:5--
U
PROCUREMENT DIVISION USE
DATE RECEIVED IN PD
RECORDED BY
SECTION ASSIGNED TO
NEGOTIATOR
...-----
FORM ouriAREPLAcEs FORMS
A.A7 4--re-V 2420 AND 24161 fl UNCLASSIFIED El CONFIDENTIAL rn SECRET I J (specify)
Declassified in. Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7 38)
Li UNCLASSIFIED LI - CONFIDENTIAL I I SECRET I
ATTACHMENTS CR STATEMENTS (specify)
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7
The builder of the HPSC is the only contractor with enough
intimate knowledge of the equipment to assemble the Diagnostic
Computer Program.
2. PROPOSAL
Attached
3 DELIVERABLE ITEMS
REPORTS REQUIRED
NO. .OF COPIES F-XI MONTHLY 1-1 INTERIM
I I
QUARTERLY
FINAL
HARDWARE (state type and number) Required 'components to modify HPSC
Six (6) copies of instruction manual for use of Diagnostic Computer
One (1) or more punched paper tapes of comparator program
One (1) copyof-a computer generated ."listing" of the Diagnostic
Program, including flowchart diagrams of this computer program.
OTHER
Pro
4. GFE REQUIRED
Requires use of HPSC, and a pair of stereo test photographs
described in attached proposal.
5. SPECIAL INSTRUCTIONS
El UNCLASSIFIED [Ti CONFIDENTIAL I I SECRET I I (specify)
Declassified in Part - Sanitized Copy Approved for Release 2012/08/24: CIA-RDP79B00873A001400010002-7