CONTROL MEASURING INSTRUMENTS

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP80-00809A000600360620-3
Release Decision: 
RIPPUB
Original Classification: 
C
Document Page Count: 
3
Document Creation Date: 
December 22, 2016
Document Release Date: 
July 22, 2011
Sequence Number: 
620
Case Number: 
Publication Date: 
December 4, 1950
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP80-00809A000600360620-3.pdf203.03 KB
Body: 
Sanitized Copy Approved for Release 2011/07/22 :CIA-RDP80-00809A000600360620-3 !NFORMATION FROM FOREIGN DOCUMENTS OR RADIO BROADCASTS CD NO. CENTRAL INTELLIGENCE AGENCY REPOR~ G Y' CLASSIFICA"rION CoNFioErrDiAL COI~FIDEI~~I~t COUNTRY USSR SUBJECT Scientific - Electricity, instruments HOW PUBLISHED Monthly periodical WHERE PUBLISHED Moscow DATE PUBLISHED Sep 1950 LANGUAGE Russian TMIt DOCYY tYT COMTAIYt IMIOtYAT10A AI{[RIM[ iN[ YATIOYAL D[I[Yt[ 01 :N[ YYIT[0 tTAT[t YITMIY TN[ YGYIYY 01 [t-IOYMt Att t0 V. t. C., tl AMD fl. At AY[t D10. ITt TAANt ^IttION OY 7N[ ttYtL1TI0Y 01 lit COYTINTt IY AYT YAM Mtt TO AN YMAYTNO[II[O Itt10N +t I[O? Nltlit0 tT LAY. Yl-t00Ytt10Y 01 TNIt IOtY It IYOMI[IT[0. SOURCE Elektrichestv~, No 9, 1950. DATE OF INFORMATION 1950 DATE DIST. ~ Dec 1950 N0. OF PAGES 3 SUPPLEMENT 'i'O REPORT NO. THIS IS UNEVALUATED INFORMATION CONTROL MEASURING INSTRUMENTS , , , , , s? , , , and 15,000 amp. Frame dia- meter 185 mm, height 75 mm (frame) plus 52 mm (current-carrying leads), ? Weight 1.33 kg. EMM -- Electromagnetic ammeters, small. The 'same as Type ENM ammeters except that ammeters with maximum readings of 100, 150, and ..200 amp for direct connection are not made. Frame diameter 135 ~, height 73 m~; (frame) plus 52 mm (current-carrying leads), Weight'o.8 kg? ormera, 7.5, 10, 15, 20, . 30, 40, 50' 75, loo, 150, 200, 300, 400, 600, 750, 1,000, 1,500, 2,000, ~?`~_? 3,ooc, 4,000 5 000 6 000 7 Goo 10 000 ? Compiled by"Engr R.~.? Gel'man The following types of control measuring instruments, listed on sheet 57 of the Handbook .of Power Plant Engineering, are manufactured by the Ministry of Machine and Instrument Euilding USSR: ENM -- Electromagnetic ammeters, ordinary, With magnetic damping, for 50 cycle ac circuits. Accuracy class 2,5 rpercen~. Maximum read- 3ngs: (a) for direct connection, 1, 2, 3, 5, 10, 20, 30, 50, 75, 100, 150 and 200 amp; (b) for use with current transf MN -~ Magaetoelectric ammeters, ordinary, Far use in do circuits. Accuracy class 1.5. Maximum readingsi (a) with internal shunt, 1, 2, 3, 5, 10, 20, 30, 50, 75, 76, and 100 amp; (b) with shunt connected +.xacrosa calibrated leads, 150, 200, 300, 500, 750, 760, 1,000, 1,500, ::~ 2,00, 3,000? 4,000, and 5,000 amp, Instrument scales have zero read- ?r ing oa left or`;in center. Frame diameter 185 mm, height 75 mm (frame) ? plus 52 mm (current-carrying leads). Weight 1.6 kg. MM -- Magnetaelectric ammeters, small. For use in do circuits. Ac~nracy class 1.5. Maximum readings;.(a) with internal shunt, 0.05, 0,075, 0.076, 0.1, 0.15, 0.3i 0.5, 1, 2, 3,?.5, 10, 20, 30, and 0 am 5 p; (b) with shunt connected across calibrated leads, 75, 76, 100, 150, 200, 300, and 500 amp, Instrument scales have zero reading on .left or in center. Frame diameter 135 ~, height 73 mm (frame) plus 52 mm (current-carrying leads). Weight 1.1 kg. Sanitized Copy Approved for Release 2011/07/22 :CIA-RDP80-00809A000600360620-3 Sanitized Copy Approved for Release 2011/07/22 :CIA-RDP80-00809A000600360620-3 r ~ ~~?~!El~ENTlAt 2MU -- Dfagnetoelectric ammeters, very small. For use in do cir- cuits. Accuracy class 1.5. Maximum readings; (a) with internal shunt, 0.05, 0.075, 0.076, 0.1, 0.15, 0.3, 0.5, 1, 2, 3, 5, and 10 amp; (b) with shunt connected across calibrated leads, 20, 30, 50, 75, 76, 100, 150, 200, and 300 amp. Instrument scales have zero reading oa left or in center. Frame diameter 110 mmr, height 66 mm (frame) plus 58 mm (cur- rent-carrying leads). Weight 0.9 kg. ENM -- Electromagnetic voltmeters, ordinary. With magnetic damping, for use with 50 cycle ac circuits. Accuracy class 2.5. Maximum readings: (s) for direct connection, 15, 30, 50, 150, 250, 460, and 600 v; (b) for use with voltage transformers, 3,600, 7,500, 12,000, 18,000 and 42,000 v. Dimensions and weight as for Type ENM ammeters (see above). EMM -- Electromagnetic voltmeters, small. For use with 50 cycle ac circuits. ?Accuracy class 2.5.. Maximum readings; (a) for direct con- nection, 15, 30, 50, 150, and 250 v; (b) for use with voltage transform- ers, 460, 600, 3,600, 7,.500, 12,0000, 18,000, and 42,000 v. Dimensions and weight as for Type EMM ammeters (see above). MN -- Magnetoelectric voltmeters, ordinary. For use with do cir- cuits. Accuracy class 1.0, Maximum readings: (a) with supplementary internal resistor, 3, 7.5, 7.6, 15, 30, 50, 75, 76, 150, 250, 300, 450, 460, and 600 v; (b) with Type VDS external resistor, 1,000, 1,500, and 3,000 v. Instrument scales have zero reading on left or in center. Re- sistance of instrument 133 ohms volt. Dimensions and xeight as Por Type iniv ammeters (see above). MM -- Magnetoelectric voltmeters, small. For use with do circuits. Accuracy class 1.0. Maximum readings: (a) with internal resistor, 3, 7.5, 7.6, 15, 30, 50, 75, 76, 150, 250, and 300 v; (b) with Type 7.SD1 external resitor, 450, 460, and 600 v; (c) with Type VDS external re- sistor, 1,000 1,500, and 3,000 v. Instrument scales have zero reading on left or in center. Resistance of instrument 133 ohms volt. Dimen- sions rnd weight as for Type MM ammeters (see above). 2MU -- Magaetoelectric voltmeters, very small. For use with do circuits. Accuracy class 1.0. Maximum readings:;(a) '(2)'with internal resistor, 3, 7.5, 7.6, 15, 30, 50, 75, 76, and 150 v; (b) with Type 1SD1 external resistor, 250, 300, 450, and 600 v; (c) with Type VDS external resistor, 1,000 sad 1,500 v. Instrument scales have zero reading on left or in center. Resistance of instrument 133 ohms volt. Dimeasions?and weight as for Type 2MU esmietere (see above). VIT -- Induction wattmeters. For use with three-phase ac cir- cuits with unbalanced phase loading. Accuracy class 2.5. Caa be connected directly is 127, 220, and 380-v circuit.. or through volt- age fransformera is 500, 3,000, 6,000, 10,000, 15,000, and 35,000-v circuits. Current rating 5 amp. Frame diameter X25 mm, frame height 147 ~? Weight 5.2 kg. ? VIN -- Induction wattmeters. For use with three-phase ac cir- cuits with balanced phase loading, the generator windings being ccn- nected by a star connection with the neutral point brought out. Ac- curacy class 2.5. Can be connected directly in 220 and 380-v cir- cuits and through voltage transformers in 3,000, 6,000, 15,000, and 35,000-v circuits. Current rating 5 amp. Dimensions and weight as for Type,VlT wattmeters (see above). Sanitized Copy Approved for Release 2011/07/22 :CIA-RDP80-00809A000600360620-3 Sanitized Copy Approved for Release 2011/07/22 :CIA-RDP80-00809A000600360620-3 CONFIDENTIAL VIO -- Induction wattmeters. For use with single-p}aese.ac circuits. C'~sracteristics and dimensions as for Type VIT wattmeters (see above). weight ~.3 kg. FVT -- Ferrodynamic wattmeters. Will come into use in the second half of 1950. Fixed, for three-phase ac circuits with unbalanced phase loading. Acouracy class 2.5. Can be connected directly in 100, 220, sad 380-v circuits and through voltage transformers in 380, 500, 3,000, 6,000, 10,000, 15,000, and 35,000-v circuits. Current rating 5 amp. Frame diameter 185 mm, height 95 mm (frame) plus 52 mm (current-carrying leads). Sanitized Copy Approved for Release 2011/07/22 :CIA-RDP80-00809A000600360620-3