VEB VAKUTRONIK DRESDEN: PRODUCTION OF COUNTERS AND RADIAC MEASURING INSTRUMENTS

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP80S01540R007400070001-8
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
8
Document Creation Date: 
December 20, 2016
Document Release Date: 
January 25, 2008
Sequence Number: 
1
Case Number: 
Publication Date: 
September 20, 1956
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP80S01540R007400070001-8.pdf307.4 KB
Body: 
Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 44 Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Approved For Release 2008/01/25: CIA-RDP80S01540R007400070001-8 PROCESSING COPY REPORT INFORMATION INFORMATION . CENTRAL INTELLIGENCE AGENCY. , This material contains information affecting the National Defense of the United States within the meaning of the. Espionage Laws, Title 18, U.S.C. Secs. 793 and 794, the transmission or revelation of which in any manner to an unauthorized person is prohibited by law. 25X1 S-E-C-R-E-T DATE OF INFO. PLACE & DATE ACQ. DATE DISTR. 20 Septeiri#her 1 6 REQUIREMENT NO. 1. The VEB Vakutronik, Dresden A 21, Dornbluetstrasse 14, has completed arrangements to begin series production of radiac and measuring instruments. During the first phase of the program, the following items will be produced in quantity: 410,420,430) STATE X ARMY X NAVY X AIR Item Impulse densimeters Electronic decade counters (Zaehldekade) Impulse measuring desk Impulse counters Small ray indicators (Strahlenindikatoren) GeigerMueller counter tubes of various types FBI X ORR X OSI X Approved For Release 2008/01/25: CIA-RDP80S01540R007400070001-8 Production of Counters and Radiac Measuring Instruments VA-Z-111,112,113) it 310,320 ) Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 N ,, L- V-L7 'J .t1 L) J J. '.1 :i1~ i1111~.J 1JL' lY . ' 1. VEB VAKUTRONIK, DRESDEN A 21, Dornb tits Grasse 14, have arrdrio rrc~i n hand to begin series production of radiac and measuring Instru-nents. 2. For the first stage of their pro _:-ramme, V~EB V.'d1,UTRONTK produce in quantity: Type No. (a) Impulse densimeters VA-G-40 (b) El.ectronic decade counters VA-B-01 (Zah1 dokade (c) Impulse measuring ieak VA-G-20 (d) Impulse counters VA-G-21 (e) Small ray indicators VA-3-OL (Strahlenindikatoren) (f) Geiger A,2tiller counter tubes of VA-Z 111 various types VA-Z 112. VA-Z 113 VA-Z 310 VA-Z '320 VA Z 410 VA Z 420 VA Z 430 3. A description of each instrument with its technical specifications follows in the l emainder of this report: 4. I VWULSE DE NSIMETER. - TYPE VA -G-10 Genoral #h(, Impulse Doiisimeter makes possible continuous moasurement of impulse densities of periodically and statically divided impulse sequences. It is suitable for use in conjunction with Geiger Muller counters as a simple laboratory device for solving nuclear physical measurement problems, deter :lining radiation intensities and resolving such technical questions us non-destructi-re testing of matrials, safety control, etc. /T:;chnical Data: Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Technical Data Input Sensitivity: 0.28 V Indication cf Impulse Density: Measurin5 Range Release Time (Aufl~sungszeit) 600 Imp/min 3 as 1,800 6,000 0.3 18,000 0.1 60,000 0.03 ..,latching Control: By means of the mains freq ency. Integration period: 5 - 30 s, continually controllable . i 10% l\'Ioasuroment of v.ry slight intencities: Through 4-position roller counter. Release time 60 ms. Counter cannot be switched back, Acoustic Indication: Through built-in miniature speaker (KleinMrer) High Tension: 0 - 1,600 V for coarse and fine tuning stabilized to ? 2% at + lCr% mains fluctuation. Possible connections: To recorder and impulse counter. Input: 5. ELECTRONIC General This instrument is desi0i ed to facilitate self construction of electronic counters. The decades can be switched directly in series. Technical Data Input Impulses: Amplitude: Rate of rise: Output Impulses: 220 V 50 c/??, alternatively '10 or 127 V. ca. 60, VA 550 x 290 x 240 mm. 15 - 30 V negative. Suitable for modulating other decade counters 5 us Flashing laps (Glim:ilampen) /Feed: Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 RFPRFT Anode torsion Anode current Filament volt?n,ge Filament current 330 v - (? i0%) ca. 30 mA 6.3V'?(- 10a ) 1.8 A 0.6 A 1.94x180x59 -mrn., ircludling valves. 6. MEASURING DESK TYPE -VA-G-20 General (i) This laboratory instrument is doeignol to count single impulses and simultaneously to enable their dositios to be measured. It is equipped with an automatic device to allow hand s,-,;itching as Tell as measurement by impi lso selection. The duration in time of any measurement is automatically shown 1?;;r a stop-clock and there is a switch-clock connection for preselected time ?easur s nts. (ii) The desks consists of three sound boards (EinschUben) placed in a single housing. The lower board will take, as desired, the VA-G-40 or VA-G-41 type impulse densimeter nigh tension supply for the counter. The release +i.nos (1'>ufl8sungszoiten) given in para.4 above for the impulse densimetcr apply :-:hen the impulse counters are connected. (iii) The upper and cent -e -boards take the electronic and mechanical impulse counter equipment -,which can be used in connection with other measrrements which rely on the countor principle - e.g. short-ti.e measurements. Technical Data Impulse Counter Release Time: 5 us. Counter Speed: max. 10,000 Imp/s. Counter capacity: 106 Imp. Counter Syste.: In decodes: 2 electronic decades 2 mechanical decades. Impulse Selection: Time Miea.~3urement Connections: Can be reset. 102, 103, 104, 105, 106 Imp. Built-in stop-clock to 30 min. The direct input of the impulse counter corresponds to impulse and sine-shaped potentials (Spann'maen) of the order of 3 V. SECRET Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Details as for VA-G-40 and \TA-G-41 Impulse Densimeter The Measuring Desk as a whole Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Para.6 (cont...) Power Supply: Input- Moasuranonts - 7. IM,TJLSE COUNTER - TYPE VA-G-21 General 220 V 50 c/s; or 110 and 127 V. c. 200 VA 600x550x200mm. This counter is designed for economy of zrorking in radiation labora- tories. Used in conjunction ith Geiger-Muller counters it permits counts of single impulses. Technical Data Input Sensitivity: Release Time- Councor Speed. Counter Capacity: Counter s Tstem: Voltage- Poorer Supply: input - Measuronients - 8. SMALL RAY IPDICLTOR - TYPE VA-J-OL 0.25 V. 30 us max. 1500 Imp/s. 106 Imp. decades electronically 4 mechanically 0 - 1,600 V Coarse and fine tuning No indicator Stabilized to ? 2% at 10% current fluctuation. 220 V at 50 c/s3 or 110 or 127 V. ca. 120 VA 400 x 220 x 220 mm. General This is a sr_all manageable device intended to determine the position of radioactive substances in a laboratory and on the t-round. Counter impulses are detcr_rined acoustically through head-phones. /Technical Data- Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 para., g _Approved For Release 2008/01/25: CIA-RDP80SO154OR007400070001-8 T7seo R13ntgon, Gamma and Beta rays from 0.5 MoV. Technical Dataa,O Ray Detector: Geiger Muller counter Battery Feed: 5Vorcing life of about 50 hours Measurements: 220 x 45 x 55 mm. 7. GEIGER i fl LLER COUNTER TUBES The counter tubes shown in tee trihle belo;r arc self disch=arging (selbstlbschcnd) and ,are fitted ~. ith an oxide coat. d c thode (Scnicht - k:tithode) . With the exception of type VIZ 430 they aro fitted with coaxial standard counter i;ube sockets (Standard-Z!,hlro'rrrsockel). Type Vii- Z 111 112 -7 310 320 430 410 113 420 Thin-,galled- Window Liquid glass Counter tube Counter tube Counter tube (Fenster (Fliissig!kkeits- (Gla.s ZL.h~rnhr) Zdhlrohr) d.hlruhr) Effective 10 100 - - in ?-0 10 10 Counter volume in cmva 4 Thick.ess mg/cm ca 35 50 - - 35 35 35 35 Starting potential 1 000 (Eins-atzsp ,ainung) 1000 11000 1000 1000 1000 11000 1000 1 in V ca Minimum plan3 length (Plateau- 200 200 150 150 200 200 200 200 l .nge Plane incline 5 % 5 ' 10 /-10 5 5 5 ! 5 in % 100 V Minimum life 10 10 1 10 10 i61, 10 10 10 in Imp. ca 'firdow t~ickness - - L2 ca-3 - - - I - in mg/cm' Window diameter in cmi. - - 30 30 - - - - Measuring volume - - 10 - 50 in ml.c^,. Standard ground - - - - - - 29/32 - 29/32 .Dint Construction Bell type see Immersion see Construc- @ (Eintauch) ! tion Counter tube Discharge (Durchfluss) counter tube Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8 Next 5 Page(s) In Document Denied Iq Approved For Release 2008/01/25: CIA-RDP80SO1540R007400070001-8