TECHNICAL BROCHURE FOR THE R-4 SCINTILLATION COUNTER
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP80T00246A056200040001-3
Release Decision:
RIPPUB
Original Classification:
C
Document Page Count:
3
Document Creation Date:
December 22, 2016
Document Release Date:
June 21, 2010
Sequence Number:
1
Case Number:
Publication Date:
September 1, 1960
Content Type:
REPORT
File:
Attachment | Size |
---|---|
![]() | 1.04 MB |
Body:
Sanitized Copy Approved for Release 2010/06/21 : CIA-RDP80T00246AO56200040001-3
I N FORMATION REPORT INFORMATION REPORT
CENTRAL INTELLIGENCE AGENCY
an unauthorized Pew prohibited by law.
This materw contains information affecting Me B U.S.C. secs. 793 and 794, the transmission or revelation rof~ whiof the United ch in an manna to within
C-O-N-F-I-D-E-N-T-I-A-L
NOFORN
nian SSR) REPORT
t
E
s
o
COUNTRY USSR (
1. (L 5
SUBJECT Technical Brochure for the R-4 DATE DISTR.
Scintillation counter
NO. PAGES 1
REFERENCES RD
DATE OF
INFO.
PLACE 8,
DATE A
1. An Estonian-language brochure, entit..ed Radioaktiivne torude seinapa suse
ja selle erinevuste mootja, containing a picture, technical data, and
description of the operating principles of the R-4 scintillation counter
produced by the Tallinn Experimental Plant for Control and Measuri
Devices
2. The R-4 is used for measuring the thickness of the walls of tubing and of
sheet material. In tubing, the thickness and deviations therein may be
measured in steel tubes with walls, up to 5 m Lprobably mm is mean thick,
and in aluminum and plastic tubes with walls up to 20 mm. The tubes may
be from 30 to 120 mm in diameter. Sheet materials of steel, aluminum,
or plastic, with thicknesses corresponding to those of the tubes1may
also be measured. The radiation source is a crystal of sodium iodide
activated by thallium204, with an activity of 20 mC. The device operates
on an alternating current of 220 V, 50 cycles. A fluctuation of plus
or minus 10 percent in the voltage does not influence the accuracy of
the measurements. The size of the device is 230 by 190 by 230 mm and it
weighs 7.9 kilograms.
3. When removed from the covering report, the brochure is UNCLASSIFIED.
C-O-N-F-I-D-E-N-T-I-A-L
NOFORN
ARMY x NAVY X lAIR X N/A 11 X OCR X NIC X
$TAT9 X
"
"
#
.)
(Heft: Washington distribution indicated by "X"; field distribution by
Sanitized Copy Approved for Release 2010/06/21 :
Sanitized Copy Approved for Release 2010/06/2
CIA-RDP80T00246A056200040001-3
Sanitized Copy Approved for Release 2010/06/21
CIA-RDP80T00246A056200040001-3
Sanitized Copy Approved for Release 2010/06/21
CIA-RDP80T00246A056200040001-3
ERINEVUSTH-PdQOTdA P-4
seinapaksuse erinevuste kontroll miseks, torn seinapaksus?,: La lehtmater-
gusalIikaks' on isotgop, al iii 20, ax'Lnvsu 0
a mat ztite seine
T-1 ,
alunrimumi ja plastxnasside p'uhul
ei ase punul
torude labimoot-
a): torude" seinapaksust la ,se11e' ermevusi;
Pinge koiklzmme ?10Ly," mojuta moatmist le;?iusi
Gabarudid 230X190Xi230,ixlm,,,."
Kaal 7,9 kg;
Sanitized Copy Approved for Release 2010/06/21
CIA-RDP80T00246A056200040001-3
miga;aktiveeritud naatiiumlodndi kri a ist la fot oidis Est 3
Luminestsex tskristallV stsintillatsi o i tagalarjei fot o isti
vad elektrumpulsic suunatakse In i f se,t mis koosneb o nendi i
graatorist j~`,lampvoltmeetrist V,n ne moodab pm t, mis' a verde=
line impulsside sagedusega ' /";
Voimezidit ja lampvoltmeetr~ t detakse` labs st iJaatori
-1 11 11 kum 5 ,
(12O
Muni 5 mm
ku 4' 20 rrin
ink A.,
x Rlst P-4 pghineb konti ollitavas esem S eeld ud kur
rolhtavalt mater~ahlt peegeidunud, Ilse rote its
Kzirgu e vastuv~tlaks on .stsmtill tsi oendaja,`~ k
oflI-14loodur1l
sta g Katsetehas,? TaIliian,
ENSY RMI J,
IL INFOR]UTA SI ONI Bt7R00
Trukikoda cUhi~el? Tallinn: Tell 2342 ~Vi`1960: 'Tiraa 3000:'