THE IVANOVO COAL MINE

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP82-00457R006800100015-7
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
2
Document Creation Date: 
December 14, 2016
Document Release Date: 
March 21, 2001
Sequence Number: 
15
Case Number: 
Publication Date: 
February 2, 1951
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP82-00457R006800100015-7.pdf155.11 KB
Body: 
t 0 JNTRY `rugosla rla DATE DISTF .. 2 P P,3 51 SUBJECT The Ivanovo Coal Mine NO. OF PAGES TIP 2 25X1 A~ SCE ? NC7 OF ENCLS DATE 0 INFO. Approved For Rele.v,5w2 Qi 4tOlt, A- R&-004578 m0 tp o R (LISTED BELOW) 25X1X SUPPLEMENT TO REPORT NO. 1. The Ivanovo coal mine is located approxtmately six kilometers southwest of Zajecar,, and at the northeastern end of the village of Ljubnic?a. The mine is connected with the Zvezdan loading station by an overhead r=ope ay four kilometers long. The mine also has a road connection with the ZaJecar?,..Boljeva.c-Ljubnica road. 2. The mine is administered? by the directorate of the Zajecar rros; which is directly subordinate to the Ministry of Mines of the Republic of serbl a in Belgrade? The planned production figures for 1949 and 1950 are as follows: 19459 - 80. ,000 tons 1950 - 90,000 tons The total output for 1949 was 78,000 tons. The total estimated reserves are lay million tons of fair quality lgnite. 4, The mine output is consigned for domestic and industrial consumption in Belgrade and Zajecar with the exception of 0 to 1$ tons a day which are sent to the Zvezdan thereto-electric power station. 5. 3evel.,o manta: a. The overhead ropeway- connecting the rAne with Zvezdan was constructed by a Hungarian firm in 1,947. CONFIDE b, The same f r na also installed the coal separation plant which is adjacent to the Zvezdan loading station. Q.. Near house: for the workers have been constructed, 6. The mine receives electric power from the station in ZZvezdan. The punt is equipped with a single turbine of 1, 200 kilowatt capacity. A second turbine of equal capacity is being installed at the plant, but completion has been delayed owing to the non-availability of the transformer which is 1.'. in.g i- %or ?,ed from Germany. Both turbines are of German origin. MAW CONFIDENTIAL CLASSIFICATION SMM/CONTROL - U.S0 OFFICIALS ONLY Approved For Release 2001/04/01 : CIA OR- A I REPOIFIT CD NO. ~1~ Coorment Me. ---V-4,v -------------- ila tita*C. In Class. i_l dooiassifei Class. Changed Ter TS S ef 00x $.,,e~''',QQ'' Approved For R2M%HR1J24/01 : CIA-RDP82-00457R006800100015-7 SET/C0NThoL . U a S . GFFI C IALS ONLY CENTRAL INTELLIGENCE AGENCY 25X1 A i :ack~ ,ue ss~d a ui, ent: a.: The mino is equipped with the follolving machinery: 'laumatic compressors Perforating machines of Czech and Yugoslav origin, electrically operated at 125 volts. Rubber belt transporters Schutte-1 chutes Electrically operated cranes Centrifugal pumps b. The overhead ropeway is electrically operated and as a bunker of 2,000 tons capacity. c. The separation plant is fully equipped v,rith electrically operated Sieves Graters Rubber, belt transporters Chain conveyors d. The mine has its own workshops which include: Turning shop, complete with frasing, boring and turning machin s. Blacksmith shop Electrical workshop enters c shop e. The min?: owns s:. trucks of Skoda, Fiat and Praga manufacture. These trucks are serviced in the mine garage which is fairly well equipped. 8. The total number of employees is approximately nine hundred. The main factor limiting production is the shortage of labor. The mine employs an average of 5)0 forced laborers, all of whom are serving short-term sentences. They are employed as miners, and allowed to move in the. mine area freely. They are, however, required to report daily to the Militia station and forbidden to leave their quarters after dark, The m ne area is completely open and no passes are issued to the employ Branko D j ordj evi c Jellenko Engineer Turkovic Mine director Mine manager Chief engineer Approved For ReIe 1"64T01 : CIA-RDP82-00457R006800100015-7 S F /CONTROL - U.S., ( FICIAI3 ONLY