Repair Tickets
DATE:
1980
2/1
6th floor mechanical room
AHU #8 outside -dampers
3/7
- 5/6
Duct shafts 1,2,3,4
(air exhaust)
Patch walls
2/6
6th floor mechanical room
Maximum outside air dampers
AHU #6
2/6
6th floor mechanical room
Check reheats on AHU #6 & #7
2/10
Replace steam valve on Photo
Lab converter
7/23
Adj linkage on cooling tower
#4. Adj controller on mixing
valve tower N.
3/8
Unclog condensate line from
reheat coil
2/14
Repair volume damper on cold
duct system
5/5
1 N707
Clean mixing box
4/17
6th floor mechanical room
Repair steam leak
4/21
M/G Set Annex
Adj three-way valves because
house chill water is leaking
into special chilled water
system
2/15
6th floor roof
Expansion tank overflowing
6/27
4th floor roof
Condensers clean coil fins
6/27
AHU #1
Open minimum outside air dampers
7/25
ANNEX
Check sprays AHU #1,2,3
7/25
ANNEX
Spray pump and float on AHU #5
6/19
6N504
Branch line from stat leaking
4/25
4th floor wire closet
Replace defective busway switch
8/13
6th floor mechanical room
Repair leaking chill water valve
Approved For Release 2005/08/15 : CIA-RDP85-00988R000100090052-6
Approved For Ref se 2005/08/15: CIA-RDP85-00988R0 0,00090052-6
SUBJECT: Repair Tickets (Cont'd)
DATE: 1980
8/13 4th floor roof
8/25 ANNEX
8/25 ANNEX
8/25 AHU #4
9/15 6th floor mechanical room
July ANNEX
8/8 ANNEX
1978 ANNEX
August 6th floor mechanical room
Check freon level on
comparator DX Units
Control air compressors low
pressure
Automatic drain leaking on
control air compressor
Main air stays on outside air
controller when AHU is off
Repair thermometer on AHU F1
Inspect and replace rusted
out extractors.& (All air
handler)
Repair return fan 21
Repair return fan 13
Roll filters
Approved For Release 2005/08j15 : CIA-RDP85-00988R000100090052-6
Approved For Reelease 2005/08/15: CIA-RDP85-00988R00100090052-6
ATTACHMENT C
A. The GSA Contractor has failed to remove residue as needed.
There are presently 10,000 lb's of waste ac up and the problem has
existed for the past 90 days. This creates a extreme fire-hazard.
See Memo 21 Aug 80, Chief of Supply, NPIC.
B. Perimeter fence is in disrepair in numerous areas. In some areas persons
enter compound through large holes and bypass FPO control points.
STAT C. I gate inoperative due to faulty motor for 5 weeks. Gate
cannot sed in accordance with standard operating procedures.
D. There has been a fire alarm survey every two months and a fire drill
on July 1980 revealed significant defects which have not been repaired.
E. For 5 months there have been two (2) skylights broken over the loading
dock. Rain damages is causing safety problems at the loading dock area.
Approved For Release 2005/08/15 : CIA-RDP85-00988R000100090052-6