REVISION - INVERTER SYSTEM

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP89B00980R000200180012-1
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
4
Document Creation Date: 
December 14, 2016
Document Release Date: 
October 16, 2002
Sequence Number: 
12
Case Number: 
Publication Date: 
May 13, 1963
Content Type: 
FORM
File: 
AttachmentSize
PDF icon CIA-RDP89B00980R000200180012-1.pdf169.01 KB
Body: 
Approved For Release 2002/10/31 : CIA-RDP89B00980R00620A 12-1 ENGINEERING STUDY a LOH CEED. AIF CRAFT CORFORAMON -156 CHANGE PROPOSAL DATE 13 MAY 1963 AFFECTS' WSPO [ PROJECT NAME OF MAJOR COMPONENT PART OR LOWEST SUBASSEMBLY PART NO. & MODEL OR TYPE TITLE OF PROPOSAL REVISION - INVERM SYSTEM NATURE OF PROPOSAL: SEE PAGE2 REASON FOR PROPOSAL PAM2 , j- ESTIMATED COST AND TIME INVOLVrQ": ES !// ADDITIONAL FUNDING REQUIRED : ESTIMATED COST FOR KITS OR PARTS : SEE PAGE 1. C P ADDITIONAL FUNDING REQUIRED YFS (SP-1422) 1oi (SP-1923) ITEMS AFFECTED BY PROPOSAL SAFETY MISSION PERFORM- OPERATING INTER- WEIGHT OR TOOLS & MAINTE- SERVICE FLIGHT MAIN'fE. EFFEC. TIVENESS ANCE PROCEDURE CHANGE- ABILITY WEIGHT & BALANCE SUPPORT EQUIPMENT NANCE PROCEDURE LIFE MANUAL NANCE MANUAL Fx] [i] El G1 2 G1 1A EST. MAN/HRS. REQ'D. TO ACCOMPLISH CHANGE IN FIELD 80 Hours SOURCE OF PARTS FOR KIT . AVAILABILITY - WEEKS AFTER APPROVAL PURE & FAB. SEE PAGE 4 'SPOSITION OF SPARES AFFECTED - 419-2 nmmm - RETURN To STOCK FOR USE 'ED BY : Approved For Release 2002/10/31: Clkg&%W0098W0200180012-1 PRO ..F.IA Approved For Release 2002/10/31 CIA-RDP89B00 0 0 200180012-1 Page 2 of 4 RUSON FOR PROPOSAL To provide more reliable, larger capacity Inverter and to provide inverter back-up in the event of as inverter failure. Loads on the 500 VA inverter are near maxizmim under certain flight configurations end future modifications requiring additional inverter power cannot be accomodated. This proposal alloys for growth in addition to eliminating'the carbon stack regulators which have been. the source of moat ; of the past inverter :fal.3ures. XAT= OF PROPOSAL circuits for 'voltage. and frequency. regulation. Replace the- aid stir 500 VA inverter with a 4T50 VA. unit - Leland PIN 2..100 per' M817 le 'T'his inverter provides Static electronic in event of failure of the 750 VA inverter. Replace the existing inverter toggle switch in the cockpit with a rotary selector switch. with positions labeled as follows: and to pro4ide use of the ousting 25.0. VA cent iuous ignition .avert %r and the 100 VA mwgency invrter as back-up to supply aircraft 3.oa&s Revise the existing inverter eir uita to accept the 750 VA inverter - 1. OFF - All inverters off. (Notes The 250 VA inverter will be an if activated by a separate switch for use by the continuous ignition system.) 2. NORMAL a. The 750 VA inverter is turned on and all selected inverter loads are conn,e'cted to its output. Total load, including the Rendezvouts. Beacon is 544 VA* b. The Inverter Out yarning light is connected to the 750 VA inverter. c. Allows use of the 250 VA inverter for continuous ignition by placing the ?'uel Boost Pump switch in the On position. Alternate With 618T-3 -.To be selected by the pilot in the event of failure of the 750 VA inverter. a. Connects the 100 VA emergency inverter to power the eariatirig emergency flight systems, e. g. Remote CceWase, I1 5O, ADF, VOR-RMI,.Altitud.e Gyro, and HOT. Total load Is 90.2 VA. Approved For Release 2002/10/31 : CIA-RDP89B0098OR000200180012-1 Approved For Release 2002/10/31 : CIA-RDP89B00980R00020 A Q G-1 Page.3 of 4 Nature Of Proposal (Cont'd.) b. Switches Continuous ignition to the AC generator and reconnects the 250 VA inverter to provide 3-phase power to all remaining aircraft systems except the rendezvous beacon. Total load is 249 VA. c. Inverter Out warning is connected to the 250 VA inverter. Alternate With Beacon - Required on ARS aircraft only. To be selected by pilot 'hen beacon is needed after failure of the 750 VA Inverter. Reconnects inverters same as alternate with HP Radio except as follows s. Disconnects 618T-3 from 250 VA inverter and. renders inoperative. b. Disconnects autopilot from 250 VA Inverter.. gent - To be selectL& in the event of a DC generator failure orb afaailure of both the 750 VA and 250. VA interters. c. Disconnects gamma pulse rate inter from 250 VA invert d. Connects rendezvous beacon to 250 VA inverter. Total load on the 250 VA inverter is 255 VA. a. Turns off the 750 VA inverter. b. Turns off the 250 VA inverter. c. Turns on the 100 VA inverter to supply emergency flight instruments onlyt d. Connects the inverter out yarning light to the 100 VA inverter. Relays for accomplishing the load monitoring and inverter switching will be provided in the Q-bay. An isolation transformer vill be added to the B phase to permit additional B phase loading and more evenly balance the loading of the three phases. The new 750 VA inverter provides approximately 200 VA in excess of present loads. This will be available for future modifications, but the 250 VA inverter, when used for back-up in the event of main inverter failure, is fully loaded, and all future modifications must provide for selection of monitored e9pipment to avoid overloading the 250 VA Inverter. Approved For Release 2002/10/31 : CIA-RDP89B0098OR000200180012-1 25X1 STAT Approved For Release 2002/10/31 : CIA-RDP89B0098OR000200180012-1 Approved For Release 2002/10/31 : CIA-RDP89B0098OR000200180012-1