Published on CIA FOIA (foia.cia.gov) (https://www.cia.gov/readingroom)


AMPERIF SOLID STATE DRUM

Document Type: 
CREST [1]
Collection: 
NGA Records (Formerly NIMA) [2]
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP94T00858R000600900001-4
Release Decision: 
RIFPUB
Original Classification: 
K
Document Page Count: 
9
Document Creation Date: 
December 28, 2016
Document Release Date: 
July 21, 2008
Sequence Number: 
1
Case Number: 
Publication Date: 
April 13, 1983
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP94T00858R000600900001-4.pdf [3]306.26 KB
Body: 
Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 NDS OPERATIONS PROCEDURE MANUAL SYSTEMS SW & HW 13 April 1983 SYMBOLIC TITLE: SSD ORIGINATOR: Approved For Release 2008/07/21 : CIA-RDP94T00858R000600900001-4 i Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 INDEX PAGE 1.1 Scope . . . . . . . . . . . . . . . . . . . . . . . i-i 1.2 Power-Up Procedures . . . . . . . . . . . . . . . . 1-1 1.2.1 UPS . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2.2 Power-Up Amperif Solid State Drums (SSD). . . . . . 1-1 1.3 Initialize The Solid State Drum . . . . . . . . . . 1-2 1.3.1 Reset The Solid State Drum (SSD) System . . . . . . 1-2 1.3.2 Restore Data Files To Solid State Drums (SSD) . . . 1-2 1.3.3 Set Time-Of-Day . . . . . . . . . . . . . . . . . . 1-3 1.4 Power Down Procedures . . . . . . . . . . . . . . . 1-3 1.4.1 Power Failure . . . . . . . . . . . . . . . . . . . 1-3 1.4.2 Manual Power Down . . . . . . . . . . . . . . . . . 1-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 15 December 1981 DATA SYSTEMS OPERATIONS BRANCH Operator Procedures Amperif Solid State Drum (SSD) Subsystem DCOB Procedure No. 1-5 1.1 Scope This document provides the operating procedures for the Amperif Solid State Drum (SSD) Subsystem. 1. 2 Power-Up'Procedures Power-up the three UPS units associated with the SSD system. This is accomplished by setting the switches located on the front control panel on each of the three UPS units as follows: a. Turn the AC'INPUT and DC'INPUT circuit breaker swiches ON. -b. Set the UPS MODE switch to OUTPUT. c. Flip the-M?=BY PASS toggle switch ON. The UPS is now operational. The UTIL ON and BY PASS ON lights will be illuminated. Before proceeding to ~Ft ee next step wait TO seconds or until the UPS AC volt meter registers 115 volts and the DC volt meter registers 96 volts. 1.2.2 Power-Up Amperif Solid State Drums (SSD) The SSD system consists of.seven cabinets. The two outside cabinets on the left and right sides of the system contain the solid state drums. The three center cabinets contain the central system with the cabinet on the right housing channel "B" and the cabinet on the left housing channel "A". The center cabinet (of the seven) contains the control unit. To power-up the SSD system: a. Assure that the UPS is in the BY PASS mode. b. Turn ON the DATA'COPY drive. The data copy device is located in the lower section of the control cabinet. The ON/OFF switch is located on the left rear of the drive. Approved For Release 2008/07/21 : CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 c. Turn power on to the three center cabinets. At the power control panel located at the top.rear of each cabinet, turn the BLWR and CU switches ON. d. Turn on power to the 4 outside cabinets (two eacTi side). At the power control panel located at the top rear of each cabinet, turn the BLWR and the four SSD switches'ON. 1.3 " Initialize'Tho 'Solid State Drum .... .... .... .... 1.3.1 Reset'The Solid State'Dr`um'(SSD) System Reset the SSD: a. Verify that the Data.copy READY light is on and the drive is in WRITE PROT' The ready light and write protect s w chi is located on the front of the Data Copy Device. b. After the Ready Light comes on, TRIP the UPS OUTPUT toggle switch on the UPS. c. At the Control Panel on.the front of the center cabinet, set.-the CHANNEL ENABLE switch to BOTH. d. Set the CHANNEL DI switch to A. e. On thekeypad epre-s e.RESET button. f. Key ' ILD and 1. When "CLEARS DISPLAY" appears on tHe-control panel TI-splay, answer YES. Key ' I LD and 3. When I'CLEAR 'SCRATCH M2Y" appears on tHcontrol panel isp ay, answer Key ILD and 7. When "CLEAR BUFFER MAY" appears on t1control panel display, answer YES. i. Key ILD and F. When "CLEAR HISTORY MM" appears on the control panel disp ay, answer YES. j. Set the'CHANNEL DISPLAY switch to T_ Repeat steps e throug 1. 1.3.2 Restore Data Files To Solid State Drums (SSD) a. Prep SSD 1 cabinet. Each of the four SSD cabinets, of which no are located on each end of the seven cabinet string, has eight prep switches which are located in the front center of the cabinet. The switches are configured with four each in two rows. 1. Turn top row PREP toggle switches ON 2. Press any RED-TM 'BUTTON in the row. 3. After the'P P lights go out, return all four switches to the OFF (down) position. 4. Repeat steps 1, 2, and 3 for the bottom row of PREP switches. Approved For Release 2008/07/21 : CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 b. Repeat step a, for SSD cabinets 2, 3, and.4. c. Restore data files. On the center cabinet control..panel..depress ' ILD..and 0. d. Wheri " DO - Y0U 'WANT DATA STORE'' appears on the dispay, answer 1.3.3 'Set'Time-Of=Day Set the timer: a. On the control panel, enter on the keypad LOAD followed by TAD. The system time is set based on a 24.hour cTock, therefore 12:30 am is entered as 0030, 2 am is entered as 0200 and 2 pm is 1400. When the display appears keyin the time HHMMSS, where HH is hour(s), NM minute (s) and SS is second(s). Depress the ENTER key. b. To verify the correct time--day has been entered, depress'DISP followed by TAD on the keypad. The current Time will appear on the display unit. If the time. is. incorrect repeat step a. c. Remove WRITE PROTECT from the data copy drive and the system is ready for normal operations. 1.4 Power Down Procedures The SSD system provides two methods for powering down the system. One is caused by a power failure and is automatic. The second is a manual opera- tion performed by the operator. 1.4.1 Power Failure The SSD System has the capability to save all Solid State Drum and system data on the Data Copy Drive in case of impending power loss. Three Data Copy Lights are provided to monitor the data copy procedure. These are located in a small box that is installed on top of the control unit. The first light, the yellow POWER FAIL light, denotes that power has been lost, and the system is running off the battery. If power is restored within one minute, this light will go off and the system returns to normal operation. If power is lost for more than one minute, the SSD System assumes that power may not be restored before the battery is exhausted and it is necessary to save all SS Drum and system data on disk to prepare for complete power loss. The second light, the green DATA COPY light, denotes when this procedure is in process. This takes only a few seconds. The third light, the red SHUT DOWN AUTH light, denotes when data copy is complete, and the system is prepared for complete power loss. The system may now be powered down safely. When powering up after a power failure, all Cache data may be restored to the pre-power failure state. This is done by doing a Data Restore after the cabinets have been reset and the SSDs are powered up. (Ref. Paragraph 1.3) Approved For Release 2008/07/21 : CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 1.4.2 Manual Power Down To power-down manually: a. Assure the 1100/84 system is inactive and stopped. b. Press 'RESET Button on the control panel keypad. c. Enter'iollowed by fd on the keypad. The response to this will be in the following sequence: a, b, c, or a, then c. 1. Message display'"DO'YOU WANT DATA RESTORE?" The response. is 2. Display is'.''STARTYNG'CYCLINDER #XXX. " ENDING CYLINDER.# ?.... The. response is NO. 3. "ENTER T ING' LINDER'NUMBER." The re- sponse is Upon completion of this entry, Data Copy is initiated. d. During the duration of Data Copy the display will indicate "DATA'COPY RUNNING" and increment cylinder numbers. Upon completion.of Data Copy the display will indicate'"DATA'COPY COMPLETE." e. Place Data Copy drive intolMITE OTECT mode. f. Power OFF all three control cabinets, and all four drum ca" inets. (Via the circuit breakers on the back panels.) g. Power'OFF the Data Copy drive. (Via the circuit breaker on the back lower left corner.) h. Power OFF all three UPS units DC Input. (Via DC input circuit breaker.) Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 l/ - j~l U r! cr i J. c 4 '7 3 SP .t ~c c ' 7 ~'~ L! ~ i?Y tic r iii --~.. ~.~jkS s/t~ /List ~/1~/~/. r ~' 'e tC vim.. ~~r C, I"/?~"n' Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21 : CIA-RDP94T00858R000600900001-4 li IAS - 432/1782 Power UP Procedures After Power Failures 1. After shutdown authorization a total cold start power up sequence must be performed.. A. Place datacopy drive into write protect. B. Power off all three control cabinets, and all four drum cabinets. (Via the circuit breakers on the back panels) C. Power off the datacopy drive. (Via the circuit breaker on the back lower left corner). D. Power off all three UPS units DC input. (Via D.C. input circuit breaker). II. Power UP Sequence A. Wait for utility power to be restored. B. Power on the D.C. input to all three UPS units. 1. Place the two drum ups unit into UPS mode. 2. Power on the datacopy drive. 3. After datacopy green ready light comes on, place control unit UPS into UPS mode (IAS-UPS). C. Power up all four drum cabinets and all three controller cabinets. D. Check that all three UPS units are still in the UPS mode. III. Resetting the Sub-system. A. Clear Routine 1. Press the reset button. 2. ILD 1- Clear SMD Display "YES" 3. ILD 3 - Clear Scratch Memory "YES" 4. ILD 7 - Clear Buffer Memory "YES" 5. ILD F - Clear History Map "YES" B. Repeat for other control unit. Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4 Power UP Procedures After Power Failures (Continued) C. Restoring data files to drums 1. Prep all drums a. b. c. Place Prep toggle switches up. Press any red prep button. After lights.go out, put all prep switches down. 2. ILDO - Do you want data restored "YES" D. Load time of day (TOD) E. Load "C" F. Display time of day (TOD) G. Remove write protect from data copy drive. Approved For Release 2008/07/21: CIA-RDP94T00858R000600900001-4

Source URL: https://www.cia.gov/readingroom/document/cia-rdp94t00858r000600900001-4

Links
[1] https://www.cia.gov/readingroom/document-type/crest
[2] https://www.cia.gov/readingroom/collection/nga-records-formerly-nima
[3] https://www.cia.gov/readingroom/docs/CIA-RDP94T00858R000600900001-4.pdf